TMP92CF26AXBG Toshiba, TMP92CF26AXBG Datasheet - Page 492

no-image

TMP92CF26AXBG

Manufacturer Part Number
TMP92CF26AXBG
Description
Microcontrollers (MCU) TLCS-900/H1 ROMLESS 144KB RAM
Manufacturer
Toshiba
Datasheet

Specifications of TMP92CF26AXBG

Processor Series
TLCS-900
Core
900/H
Data Bus Width
16 bit
Program Memory Type
ROM
Program Memory Size
8 KB
Data Ram Size
144 KB
Interface Type
I2C, I2S, UART, USB
Maximum Clock Frequency
80 MHz
Number Of Programmable I/os
136
Number Of Timers
10
Maximum Operating Temperature
+ 50 C
Mounting Style
SMD/SMT
Package / Case
FBGA-228
Development Tools By Supplier
BM1040R0A, BM1055R0B, SW96CN0-ZCC, SW00MN0-ZCC
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 6 Channel
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA
Quantity:
4 000
Part Number:
TMP92CF26AXBG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
SPICT<TXMOD> bit.
when the UNIT-size data is loaded into the SPITD register where SPICT<TXE> = 1, or
when the SPICT<TXE> is set to 1 after loading one UNIT-size data into the SPITD register.
During the data transmission, it is prohibited to change the transmission mode from
Sequential to UNIT, or vice versa.
data is loaded from the transmit data register (SPITD) to the transmit shift register. Also,
the TEND interrupt is generated upon completion of the transmission of the last UNIT
data.
SPICT<TXMOD> bit. The 32-byte FIFO is enabled in Sequential mode.
Otherwise, the TEMP interrupt is not properly generated.
sequentially when SPICT<TXE> = 1. The transmission in this mode can also be started by
setting the SPICT<TXE> bit to 1 after writing the transmit data into the transmit FIFO.
The transmit data is transmitted in the same order as they were written into the FIFO.
Therefore, the Sequential-mode transmission continues as long as the transmit FIFO (32
bytes) has any valid data. During the data transmission, it is prohibited to change the
transmission mode from Sequential to UNIT, or vice versa.
Differences Between the UNIT-mode and Sequential-mode transmissions
The UNIT
The transmit FIFO buffer is disabled in UNIT mode. The UNIT-mode transmission starts
In the UNIT-mode transmisison, the TEMP interrupt is generated when the transmit
The Sequential mode for the data transmission can be selected by writing a 1 to the
In this mode, the data writes to the transmit FIFO must be performed in 16-byte units.
In the Sequential-mode transmission, transmit data written into the SPITD is loaded
This mode of transmission keeps transmitting data as long as the transmit data exists.
Important Note:
Don’t touch to all other SFRs, TXE=1 and UNIT transmission will finish completely.
In case of using UNIT mode: TXMOD=0, there is one restriction.
Program Sample1:
Wait:
Program Sample2 (Recommend):
mode for the data transmission can be selected by writing a 0 to the
LD
DI
SET 3,
BIT 1,
JPZ,
RES 3,
EI
Check to transmission end flag! (SPIST<TEND>=1)
LD
DI
SET 3,
RES 3,
EI
(SPITDx), A
(SPICT)
(SPICT)
(SPITDx), A
(SPICT)
(SPIST)
Wait
(SPICT)
92CF26A-491
; “A” is tranmission data
; Disable Interrupt
; TXE=1: Enable and Start
; TXE=0: Disable
; Enable Interrupt
; “A” is tranmission data
; Disable Interrupt
; TXE=1: Enable and Start
; Wait to finish transmission 。
; TXE=0: Disable
; Enable Interrupt
TMP92CF26A
2007-11-21

Related parts for TMP92CF26AXBG