UPD70F3737GC-UEU-AX Renesas Electronics America, UPD70F3737GC-UEU-AX Datasheet - Page 733

no-image

UPD70F3737GC-UEU-AX

Manufacturer Part Number
UPD70F3737GC-UEU-AX
Description
MCU 32BIT V850ES/JX3-L 100-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Lr
Datasheet

Specifications of UPD70F3737GC-UEU-AX

Package / Case
*
Voltage - Supply (vcc/vdd)
2.2 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Speed
20MHz
Number Of I /o
84
Core Processor
RISC
Program Memory Type
FLASH
Ram Size
8K x 8
Program Memory Size
128KB (128K x 8)
Data Converters
A/D 12x10b, D/A 2x8b
Oscillator Type
Internal
Peripherals
DMA, LVD, PWM, WDT
Connectivity
CSI, EBI/EMI, I²C, UART/USART
Core Size
32-Bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3737GC-UEU-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Main clock
Subclock (MCK bit of
PCC register = 0)
Subclock (MCK bit of
PCC register = 1)
Internal oscillation clock
During reset
23.4 Operation
CPU Operating Clock
This section explains the functions of the clock monitor. The start and stop conditions are as follows.
<Start condition>
<Stop conditions>
Notes 1. Internal oscillator can be stopped by setting the RCM.RSTOP bit to 1.
Enabling operation by setting the CLM.CLME bit to 1
• While oscillation stabilization time is being counted after STOP mode is released
• When the main clock is stopped (from when PCC.MCK bit = 1 during subclock operation to when PCC.CLS
• When the sampling clock (internal oscillation clock) is stopped
• When the CPU operates with the internal oscillation clock
2. The clock monitor is stopped while internal oscillator is stopped.
3. Internal oscillator cannot be stopped by software.
bit = 0 during main clock operation)
(When CLM.CLME Bit = 1, During Internal Oscillation Clock Operation)
HALT mode
IDLE1, IDLE2 modes
STOP mode
Sub-IDLE mode
Sub-IDLE mode
Operation Mode
Table 23-2. Operation Status of Clock Monitor
Preliminary User’s Manual U18953EJ1V0UD
CHAPTER 23 CLOCK MONITOR
Oscillates
Stops
Oscillates
Stops
Oscillates
Stops
Stops
Status of Main Clock
Oscillates
Oscillates
Oscillates
Oscillates
Oscillates
Oscillates
Stops
Status of Internal
Oscillation Clock
Note 1
Note 1
Note 1
Note 1
Note 1
Note 3
Operates
Operates
Stops
Operates
Stops
Stops
Stops
Status of Clock
Monitor
Note 2
Note 2
Note 2
733

Related parts for UPD70F3737GC-UEU-AX