HD64F2218UTF24 Renesas Electronics America, HD64F2218UTF24 Datasheet - Page 473

IC H8S MCU FLASH 128K 100-TQFP

HD64F2218UTF24

Manufacturer Part Number
HD64F2218UTF24
Description
IC H8S MCU FLASH 128K 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2200r
Datasheets

Specifications of HD64F2218UTF24

Core Processor
H8S/2000
Core Size
16-Bit
Speed
24MHz
Connectivity
SCI, SmartCard, USB
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
69
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
12K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 6x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
For Use With
3DK2218-SS - KIT DEV H8S/2218 WINDOWS SIDESHW
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2218UTF24
Manufacturer:
RENESAS
Quantity:
14
Part Number:
HD64F2218UTF24V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
No
No
No
Figure 12.16 Sample Multiprocessor Serial Data Reception Flowchart (1)
Read ORER and FER flags in SSR
Read ORER and FER flags in SSR
Read receive data in RDR
Read receive data in RDR
Read RDRF flag in SSR
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Read MPIE bit in SCR
All data received?
This station’s ID?
FER ∨ ORER = 1
FER∨ORER = 1
Start reception
Initialization
RDRF = 1
RDRF = 1
<End>
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
Error processing
[3]
[1]
[2]
(Continued on
next page)
[4]
[5]
[1]
[2]
[3]
[4]
[5]
Rev.7.00 Dec. 24, 2008 Page 417 of 698
SCI initialization:
The RxD pin is automatically designated as
the receive data input pin.
ID reception cycle:
Set the MPIE bit in SCR to 1.
SCI status check, ID reception and
comparison:
Read SSR and check that the RDRF flag is
set to 1, then read the receive data in RDR
and compare it with this station’s ID.
If the data is not this station’s ID, set the MPIE
bit to 1 again, and clear the RDRF flag to 0.
If the data is this station’s ID, clear the RDRF
flag to 0.
SCI status check and data reception:
Read SSR and check that the RDRF flag is
set to 1, then read the data in RDR.
Receive error processing and break detection:
If a receive error occurs, read the ORER and
FER flags in SSR to identify the error. After
performing the appropriate error processing,
ensure that the ORER and FER flags are all
cleared to 0.
Reception cannot be resumed if either of
these flags is set to 1.
In the case of a framing error, a break can be
detected by reading the RxD pin value.
REJ09B0074-0700