HD64F2218UTF24 Renesas Electronics America, HD64F2218UTF24 Datasheet - Page 467

IC H8S MCU FLASH 128K 100-TQFP

HD64F2218UTF24

Manufacturer Part Number
HD64F2218UTF24
Description
IC H8S MCU FLASH 128K 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2200r
Datasheets

Specifications of HD64F2218UTF24

Core Processor
H8S/2000
Core Size
16-Bit
Speed
24MHz
Connectivity
SCI, SmartCard, USB
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
69
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
12K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 6x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
For Use With
3DK2218-SS - KIT DEV H8S/2218 WINDOWS SIDESHW
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2218UTF24
Manufacturer:
RENESAS
Quantity:
14
Part Number:
HD64F2218UTF24V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Table 12.11 SSR Status Flags and Receive Data Handling
Note: * The RDRF flag retains the state it had before data reception.
RDRF*
1
0
0
1
1
0
1
No
No
ORER
1
0
0
1
1
0
1
SSR Status Flag
Read receive data in RDR, and
clear RDRF flag in SSR to 0
PER ∨ FER ∨ ORER = 1
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Read ORER, PER, and
Figure 12.12 Sample Serial Data Reception Flowchart (1)
All data received?
FER flags in SSR
Start reception
Initialization
FER
RDRF = 1
0
1
0
1
0
1
1
<End>
Yes
Yes
No
PER
0
0
1
0
1
1
1
(Continued on next page)
Error processing
Yes
[1]
[2]
[4]
Receive Data
Lost
Transferred to RDR
Transferred to RDR
Lost
Lost
Transferred to RDR
Lost
[5]
[3]
[1]
[2]
[4]
[5]
Rev.7.00 Dec. 24, 2008 Page 411 of 698
SCI initialization:
The RxD pin is automatically designated as
the receive data input pin.
[3] Receive error processing and break
detection:
If a receive error occurs, read the ORER,
PER, and FER flags in SSR to identify the
error. After performing the appropriate error
processing, ensure that the ORER, PER, and
FER flags are all cleared to 0. Reception
cannot be resumed if any of these flags are
set to 1. In the case of a framing error, a
break can be detected by reading the value
of the input port corresponding to the RxD
pin.
SCI status check and receive data read:
Read SSR and check that RDRF = 1, then
read the receive data in RDR and clear the
RDRF flag to 0. Transition of the RDRF flag
from 0 to 1 can also be identified by an RXI
interrupt.
Serial reception continuation procedure:
To continue serial reception, before the end
bit for the current frame is received, reading
the RDRF flag and RDR, and clearing the
RDRF flag to 0 should be finished. The
RDRF flag is cleared automatically when
DMAC is activated by a reception complete
interrupt (RXI) and the RDR value is read.
Receive Error Type
Overrun error
Framing error
Parity error
Overrun error + framing error
Overrun error + parity error
Framing error + parity error
Overrun error + framing error +
parity error
REJ09B0074-0700

Related parts for HD64F2218UTF24