tmp19a43fzxbg TOSHIBA Semiconductor CORPORATION, tmp19a43fzxbg Datasheet - Page 263

no-image

tmp19a43fzxbg

Manufacturer Part Number
tmp19a43fzxbg
Description
32bit Tx System Risc
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet
(0xFFFF_F281)
SC3CR
<OERR>:
<PERR>:
<FERR>:
Note 1: All error flags are cleared to 0 when read.
Note 2: For SCLK output operation, set SCLKS to 0 (rising edge).
Bit symbol
Read/Write
After reset
Function
Receive
data bit 8
In both UART and I/O interface modes, an overrun error occurs when all bits of the
next frame have been received before data stored in the receive buffer is read out
completely. An overrun error causes the OERR flag to be set.
In UART mode, the PERR flag is set to 1 when a parity error occurs. Reading the
PERR flag clears it to 0. In I/O interface mode, the PERR bit indicates an underrun
error. When SC0MOD2<WBUF> is set to 1, an underrun error occurs in the following
case: In SCLK input mode, it occurs if data stored in the transmit shift register has
been transmitted but no data is set in the transmit double-buffer. In other modes, this
flag is not set. Reading the flag clears it to 0.
In UART mode, the FERR flag is set to 1 when a framing error occurs. Reading the
flag clears it to 0.
Figure 3.11.23 Serial Control Register (SC3CR, for SIO3)
RB8
7
R
Parity type
0: Odd
1: Even
EVEN
6
0
R/W
TMP1942CY/CZ-262
Parity
0: Disabled
1: Enabled
PE
5
0
Overrun
OERR
R (cleared to 0 when read)
4
0
Parity/
underrun
1: Error
PERR
3
0
Framing error flag
Parity error/underrun error flag
Overrun error flag
I/O interface input clock selection
Active edge selection for SCLK0 input
Parity type
0
1
0
1
0
1
Framing
Baud rate generator
SCLK0 pin input
Data transmitted/received
at rising edge of SCLK0
Data transmitted/received
at falling edge of SCLK0
Odd parity
Even parity
FERR
2
0
TMP1942CY/CZ
0: SCLK0
1: SCLK0
SCLKS
1
0
R/W
0: Baud rate
1: SCLK0
generator
pin input
IOC
0
0
Cleared to
0 when
read