CHAPTER 16: DEBUGGER
464
Interrupt level (0-15).
Interrupt type (0-215).
Invalid address or invalid CEFUNC of
parameter file.
Invalid break address.
Invalid break number.
Invalid command or parameter.
Invalid emulation memory map.
Invalid file name.
Invalid group number.
Invalid map command or invalid sequence.
Invalid memory map.
Invalid parameter.
Invalid stack map.
Invalid value of MEM33_CE (4-10).
Invalid value of MEM33_CE10EX (C00000-FFFFFF). The area 10 external memory start address is out of the range.
Invalid value of MEM33_CEFUNC (00,01,10,11). The CEFUNC is out of the range.
Invalid value of MEM33_DELAY (0-3).
Invalid value(0-65535).
Invalid value.
IROM size is too long.
MEM33 is not supported at area0, area1 and
area2 (0-0x7FFFF).
Memory verify failure.
No "END" in parameter file.
No "MEM33_CEFUNC" in parameter file.
No map area.
No symbol at the number.
Not ASCII character.
Not defined ID.
Not found input strings.
Number of emulation memory is wrong.
Number of parameter.
On tracing.
Parallel interface time out.
Parallel port is busy.
Pointer pointed no map area.
Post line range (0-256).
Pre line range (0-256).
Register variable cannot be changed to address. Addresses cannot be specified with a register variables.
Reset timeout.
Sequential break format error.
Shared RAM is busy.
Source window not opened.
Start block > End block.
Start cycle number > End cycle number.
Stdout data size.
Step range (1-65535).
Symbol is too long.
Symbol not found, xxx.
Symbol not found.
Symbol not in scope.
Target down.
Target instruction cannot be extended.
Time out.
Too many include.
Too many source file.
Top address > Bottom address.
Top address and bottom address should be
same CE.
Trace range (0-131071).
Trace range (0-32767).
Verify error.
Wrong data.
Wrong header.
1:
A time-out error occurs in the following processing if no response is returned from the S5U1C33104H within a
predetermined time:
Initial connection: 2.5 sec, Escape break: 1 sec, Map initialization: 150 sec, f or mv execution: 150 sec,
lfl or sfl execution: 150 sec, g, s, or n execution: No time-out is set, Others: 6 sec
Error message
The interrupt level is out of the range.
The interrupt type is out of range.
The address is invalid or CEFUNC of parameter is out of range.
The break address has not been set.
The break point number has not been set.
The specified command or parameter is invalid.
The emulation memory map information (.par file) is invalid.
The file name is invalid.
The command group number is invalid.
The map file contains an illegal character or incorrect sequence.
The memory map information (.par file) is invalid.
The parameter is incorrect.
The stack map information (.par file) is invalid.
The CE is out of the range.
The DELAY is out of the range.
The input value is out of the range.
The input value is illegal.
The IROM size is too large.
S5U1C33xxxM does not support areas 0, 1 and 2.
The contents of the memory and file are not matched.
There is no end mark (END) in the parameter file.
No MEM33_CEFUNC is found.
The input address is out of the mapped area.
Symbol is not registered in the specified number.
The string contains some other ASCII character.
S5U1C33104H's response ID is invalid.
The string cannot be found.
The number of emulation memory block in the parameter file is invalid.
The number of parameters in the command is invalid.
The S5U1C33104H is tracing execution data.
The file cannot be loaded through the parallel interface within the
predefined time.
The parallel port is in busy status.
The pointer variable has pointed out of the mapped area.
The number of post-display line in the trace search is out of the range.
The number of pre-display line in the trace search is out of the range.
The S5U1C33104H CPU cannot be reset.
The sequential break condition is invalid.
An S5U1C33104H internal error has occurred.
The [Source] window is closed.
The end block number is greater than the start block number.
The end cycle number is greater than the start cycle number.
The output data size in the output buffer is illegal.
The step count is out of the range.
The symbol name is too long.
Symbol XXX cannot be found.
The symbol cannot be found.
The symbol cannot be found in the scope.
The S5U1C33xxxP board does not operate correctly or remains reset.
The instruction cannot be extended by ext.
Communication time-out. 1
Number of included files exceeds the limit.
The source file is too large.
The top address is larger than the bottom address.
The top address and the bottom address are not in the same area.
The trace cycle number is invalid. (ICD mode)
The trace cycle number is invalid. (ICE mode)
Verify error when writing to flash memory.
Data in the file is incorrect.
The file header is incorrect.