s5u1c33000c Epson Electronics America, Inc., s5u1c33000c Datasheet - Page 463

no-image

s5u1c33000c

Manufacturer Part Number
s5u1c33000c
Description
Cmos 32-bit Single Chip Microcomputer S5u1c33000c Manual
Manufacturer
Epson Electronics America, Inc.
Datasheet
md (mode)
This command sets the debugger modes described below.
1. Step display for single-step execution results and [Memory] window
2. Mode of execution counter
3. ICD execution counter function (only for ICD mode)
4. Number of lines for displaying command execution results
5. cmw command wait time
6. TAB stop
7. Displaying on-the-fly information (only for ICE and ICD modes)
Since the contents set by the md command are saved to a file, the next time the debugger is started, the md
command will have the same settings as when the debugger was last terminated.
S5U1C33000C MANUAL
(C COMPILER PACKAGE FOR S1C33 FAMILY) (Ver. 4)
Step display
Execution counter mode
ICD execution counter
Number of display lines
cmw wait time
TAB stop
On-the-fly function
Function
When the step display mode is set to on, the execution results of all steps will be displayed during single-step
(s, n command) operation. When the step display mode is set to off, the execution result of only the last step
will be displayed. The register values are updated when their contents are displayed in the [Register] window;
they are displayed in the [Command] window if the [Register] window is closed. If the [Source] window is
open, the displayed lines are underlined as they are executed according to the setting of this mode.
The [Memory] window while the step display mode is on updates its display contents every step during
single-step operation or updates after a break has occurred during successive execution. When the step display
mode is off, the [Memory] window is not updated automatically. To update the window, it is necessary to
execute a memory dump command or to scroll the window.
This can be selected from the integration mode or the reset mode. In reset mode, the counter value is reset to 0
each time you enter a program execution command (including execution by the [Enter] key).
The value of the execution counter is also reset when you switch the integration mode to the reset mode.
The measurement unit of the S5U1C33000H execution counter can be selected from three types: cycle units,
second units and µsec units.
When displaying the execution results of the commands listed below in the [Command] window, you can
choose the number of lines that you want displayed at a time from 1 to 1,000 lines.
Applicable commands: db, dh, dw, sc, m, u, sy, sw, sa, sd, od, td, ts
A cmw command wait time can be set in the range of 1 to 256 seconds (in 1-second increments).
The TAB stops used in the source display can be set every 2, 4, or 8 characters.
You can choose the display interval of the on-the-fly information from 0 to 10 (times) per second. When 0 is
chosen, the on-the-fly information will not be displayed.
Mode
Integrating
ICD mode
1 second
16 lines
OFF
On
8
Default values of debugger modes
Number of cycles
EPSON
Integrating
ICE mode
1 second
16 lines
OFF
On
8
OFF (fixed)
Integrating
SIM mode
1 second
16 lines
On
8
CHAPTER 16: DEBUGGER
[ICD / ICE / SIM / MON]
MON mode
OFF (fixed)
Integrating
1 second
16 lines
On
8
447

Related parts for s5u1c33000c