od (option data dump)
This command displays option data in the [Command] window in a hexadecimal dump format after reading it
from the S5U1C33104H.
Input the start and end addresses of the display range sequentially in the order given by the guidance.
S5U1C33000C MANUAL
(C COMPILER PACKAGE FOR S1C33 FAMILY) (Ver. 4)
Function
Format
Input example
Notes
The start and end addresses can be omitted by entering the [Enter] key only.
If the start address is omitted, data is displayed beginning with address 0.
If the end address is omitted, the end address of the option area is assumed.
The maximum number of lines that can be displayed at once is 16 (default). Even if you specify the end
address in an attempt to display more than 16 lines, the db33 will only display data for 16 lines and then stand
by waiting for a command input. The following addresses are displayed by entering the [Enter] key. The
number of display lines can be changed using the md command.
Data in unused areas is marked by an "*" as it is displayed in the window.
The od command cannot be executed in the modes other than ICE mode.
Both the start and end addresses must be specified within the setup range of the option. An error results if this
limit is exceeded.
An error results if the start address is larger than the end address.
The default value of option data is 0.
od
Error: Command is not supported at present mode.
Error: Address range (0-0x3FFF). ...Specified address is outside the range.
Error: address1 > address2