CHAPTER 16: DEBUGGER
s (step)
This command single-steps the target program by executing one instruction at a time, beginning with the current
PC position.
(1) s
(2) s <step>
356
(1) Units of single-stepping operation
(2) Operation of Format 1
(3) Operation of Format 2
(4) Hitting the [Enter] key after the end of execution
Function
Formats
Operation
<step>:
Condition: 0
In this single-stepping operation, the program is executed in units of addresses or source codes – i.e., one
address or source code at a time – depending on the [Source] window's display mode as shown below:
The same function as this command input can be obtained by selecting the [Step] command on the [Run]
menu or the [Step] button on the tool bar.
The program at the address indicated by the PC executes one step.
The program executes a specified number of steps from the address indicated by the PC.
Program execution is terminated due to one of the break factors even before the specified number of steps is
completed.
When program execution is completed by stepping through instructions, the db33 stands by waiting for
command input. If you hit the [Enter] key here, the db33 single-steps the program in the same way again.
[Step] button
Disassemble display mode: Address units
Mixed display mode:
Source display mode:
Number of steps to be executed (decimal)
step
(direct input mode)
(direct input mode)
65535
Address units
Source code units