CHAPTER 16: DEBUGGER
16.3 Starting Method
16.3.1 Startup Format
General form of command line
Operation on work bench
16.3.2 Startup Options
The db33 has nine startup options available.
-p <file name>.par
Function:
Specification on wb33: Select from the file list box in the execution window.
Explanation:
-sim/-simdll-mon/-icd/-ice
Function:
Specification on wb33: Select a mode from the combo box (ICD, MON, ICE, SIM).
Explanation:
-c <file name>.cmd
Function:
Specification on wb33: Check [db33 *.cmd file] and select the command file from the list box.
Explanation:
-w
Function:
Specification on wb33: Check [1 win].
Explanation:
-comX
Function:
Specification on wb33: Select from a list box (com1, com2, com3 com4, com5, com6, com7, or com8).
Explanation:
258
db33 ^ [<startup option>] ^ -p ^ <parameter file name>
Select the parameter file and options, then click the [DB33] button.
^ denotes a space.
[ ] indicates the possibility to omit.
Specifies a parameter file (essential setup item).
Specifies debugger mode.
Specifies a command file.
Specifies a window at startup.
Specifies a communication port.
Specify a parameter file (create a template by the wb33 and modify it according to
the model to be developed).
You cannot debug a program unless you have this file.
The db33 is started up in the specified mode.
-sim
-simdll
-mon
-icd
-ice
Unless this option is specified, the db33 is started in ICE mode.
If you want a series of commands to be executed immediately after the db33 starts
up, use this option to specify a command file that describes those commands.
If you specify this option, only the [Command] window opens when the db33 starts
up. Specify this option when saving the log.
Unless this option is specified, the [Command] window, [Source] window, and
[Register] window open simultaneously.
This option specifies the communication port through which a personal computer is
communicated with the S5U1C33104H, S5U1C33000H or S5U1C330M2S. Specify a
port number (1–8) in the X part of this option. The port that can be used for this
purpose varies among different personal computers.
Unless this option is specified, the com1 port is used.
Simulator mode
Simulator DLL mode (Refer to the "S5U1C330C2S Manual".)
Debug monitor mode
ICD mode
ICE mode