s5u1c33000c Epson Electronics America, Inc., s5u1c33000c Datasheet - Page 267

no-image

s5u1c33000c

Manufacturer Part Number
s5u1c33000c
Description
Cmos 32-bit Single Chip Microcomputer S5u1c33000c Manual
Manufacturer
Epson Electronics America, Inc.
Datasheet
Relocatable object file (when restoring modules)
Error file
15.3 Starting Method
15.3.1 Startup Format
General form of command line
Operations on work bench
15.3.2 Startup Options
The lib33 comes provided with the following five types of startup options:
The actual method will be described later.
-a
Function:
Specification on wb33: Check [add]. (addition)
Explanation:
-d
Function:
Specification on wb33: Check [del].
Explanation:
-l
Function:
Specification on wb33: Check [list].
Explanation:
-x
Function:
Specification on wb33: Check [extract] (Only specified modules are restored) or [extract all] (All modules are
S5U1C33000C MANUAL
(C COMPILER PACKAGE FOR S1C33 FAMILY) (Ver. 4)
File format:
File name:
Output destination: Current directory
Description:
File format:
File name:
Output destination: Current directory
Description:
lib33 ^ [<startup option>] ^ <library file name> ^ [<object file name>]
<library file name>: Specify a library file you want to edit including the file name extension.
<object file name>: Specify a file you want to be registered, deleted, or restored including the file name
Select options and input files, then click the [LIB33] button.
^ denotes a space.
[ ] indicates the possibility to omit.
Adds an object file to a library.
Deletes an object file from a library.
Displays object files registered in a library.
Restores library modules to the original object files.
restored).
Binary file in srf33 format
<File name>.o
The specified modules are restored to the original relocatable object file.
Text file
lib33.err
File that is delivered when the startup option (-e) is specified. It records the
information which the lib33 outputs to the Standard Output (stdout), such as error
messages.
extension. Multiple object files can be specified.
If an existing library is specified, the specified object file is added to the library.
If a new library file name is specified, a library file is created from the specified
object file.
The specified object file is deleted from the specified library.
The object files in the specified library are listed in the order they are stored.
These files are listed on a standard output device (stdout).
EPSON
CHAPTER 15: LIBRARIAN
251

Related parts for s5u1c33000c