s5u1c33000c Epson Electronics America, Inc., s5u1c33000c Datasheet - Page 309

no-image

s5u1c33000c

Manufacturer Part Number
s5u1c33000c
Description
Cmos 32-bit Single Chip Microcomputer S5u1c33000c Manual
Manufacturer
Epson Electronics America, Inc.
Datasheet
ICD+MEM33 mode
Note: Specification for startup is the same as that of the ICD mode.
S5U1C33000C MANUAL
(C COMPILER PACKAGE FOR S1C33 FAMILY) (Ver. 4)
Specification for startup
Startup option:
Specification on wb33: Select [ICD]
Specify the ICD mode or ICD+MEM33 mode in the parameter file.
Refer to Section 16.11 for more information on the parameter file.
When the debugger starts in the ICD+MEM33 mode, "ICD+MEM33" appears on the tool bar.
The ICD+MEM33 mode is used to debug a program using the S5U1C33000H in-circuit debugger. If you
use S5U1C33001M1, the following break functions can be extended:
• Bus break
• Area break
• CE break
• Map break (per 32KB)
When invoking the debugger in the ICD+MEM33 mode, make sure that the S5U1C33000H,
S5U1C33001M1, and the S5U1C33208E3 are connected firmly and they are turned on.
Refer to Section 3.3.4 for details on turning them on.
Refer to "S1C33 Family In-Circuit Debugger Manual" for details on operating S5U1C33000H.
Refer to "S5U1C33001M1 Manual" for details on operating S5U1C33001M1.
Refer to "S5U1C33208E3 Manual" for details on operating S5U1C33208E3.
EPSON
Fig. 16.9.1.3 Debugging system using S5U1C33000H, S5U1C33208E3, S5U1C33001M1
COMx
(supplied with S5U1C33000H
LPTx
(supplied with S5U1C33000H
Specify -icd
Parallel cable
RS232C cable
package)
package)
S5U1C33208E3
S5U1C33xxxE
EPSON
S5U1C33000H
TRC
1 2 3 4
10pin—10pin
Target system
connect cable
(supplied with S5U1C33000H
package)
EMU
S5U1C33001M1
S5U1C33001M1
BREAK
S5U1C33000H BREAK IN connect clip
(attached with S5U1C33xxxM)
CHAPTER 16: DEBUGGER
5V
M
293

Related parts for s5u1c33000c