s5u1c33000c Epson Electronics America, Inc., s5u1c33000c Datasheet - Page 353

no-image

s5u1c33000c

Manufacturer Part Number
s5u1c33000c
Description
Cmos 32-bit Single Chip Microcomputer S5u1c33000c Manual
Manufacturer
Epson Electronics America, Inc.
Datasheet
S5U1C33000C MANUAL
(C COMPILER PACKAGE FOR S1C33 FAMILY) (Ver. 4)
(3) Number of lines displayed in the [Command] window
(4) Logging
(5) Successive display
(6) Using symbols
Notes
Both the start and end addresses specified here must be within the range of 0 to 0xfffffff. An error results if
this limit is exceeded.
An error results if the start address is larger than the end address.
In Format 3, the db33 displays data from <address1> to <address2> before it waits for command input.
Even when you specify a display range of more than 16 lines (default), display is halted at the 16th line
(same as in Format 2).
Note that the [Command] window does not display ASCII characters as shown in the [Source] window.
The number of lines displayed in the [Command] window by the db command every time it is executed is
set to 16 by default. This default setting can be changed to any value within a range of 1 to 1,000 [lines] by
the md command.
To save the command execution results to a log file, close the [Memory] window and display the results in
the [Command] window. If the [Memory] window is opened, the display contents will not be saved in the
file because the [Command] window does not display the results.
Once you execute the db command, data can be displayed successively with the [Enter] key only until some
other command is executed.
When you hit the [Enter] key, the [Memory] window is scrolled one full screen.
When displaying data in the [Command] window, data is displayed for the 16 lines (default) following the
previously displayed address.
Error: Address range (0-0xFFFFFFF).
Error: address1 > address2
EPSON
CHAPTER 16: DEBUGGER
337