peb3456e Infineon Technologies Corporation, peb3456e Datasheet - Page 378

no-image

peb3456e

Manufacturer Part Number
peb3456e
Description
Channelized T3 Termination, With Ds3 Framer, M13 Multiplexer, T1/e1 Framers And 256-channel Hdlc/ppp Controller
Manufacturer
Infineon Technologies Corporation
Datasheet
RSAW1
Receive S
Access
Address
Reset Value
SA5
SA4
Data Sheet
15
a
Word 1
: read
: 0B
: 0000
Received S
This bit field contains data received in S
CRC-4 multiframe.
E1: CRC-4 Multiframe
Received data byte is aligned to a multiframe boundary. SA5(0) is the
data bit receive in frame one, while SA5(7) is the data byte received in
frame 15 of a multiframe.
Received S
This bit field contains data received in S
multiframe.
E1: CRC-4 Multiframe
Received data byte is aligned to a multiframe boundary. SA4(0) is the
data bit receive in frame one, while SA4(7) is the data byte received in
frame 15 of a multiframe.
SA5(7:0)
H
H
a5
a4
Data Byte
Data Byte
8
378
7
a5
a4
of an E1 doubleframe or an E1
of an E1 doubleframe or an E1
SA4(7:0)
Register Description
PEB 3456 E
05.2001
0