peb3456e Infineon Technologies Corporation, peb3456e Datasheet - Page 345

no-image

peb3456e

Manufacturer Part Number
peb3456e
Description
Channelized T3 Termination, With Ds3 Framer, M13 Multiplexer, T1/e1 Framers And 256-channel Hdlc/ppp Controller
Manufacturer
Infineon Technologies Corporation
Datasheet
RLCR1
T1/E1 Receive Loop Code Register 1
Access
Address
Reset Value
LDC
LAC
Data Sheet
15
: read/write
: 03
: 0000
Line Loopback Deactuate Code
This incoming bit stream will be compared against this bit field if enabled
via bit RLCR0.LCS.
Note: Most significant bit is sent first. E.g. TCLR0.LDCL = 01
Line Loopback Actuate Code
This incoming bit stream will be compared against this bit field if enabled
via bit RLCR0.LCS.
Note: Most significant bit is sent first. E.g. TCLR0.LACL = 01
LDC(7:0)
H
H
code length to be six bits long. In this case LDC(5) is sent first.
code length to be six bits long. In this case LAC(5) is sent first.
8
345
7
LAC(7:0)
Register Description
PEB 3456 E
B
B
specifies
specifies
05.2001
0