Datasheet
XCR1
Transmit Channel Configuration Register 1
Access
Address
Reset Value
PBYTE
PCNT
INV
XON
DISCRC
Data Sheet
15
: read/write
: 03
: 0000
Preamble Byte
This bit field selects the preamble byte to be sent after interframe time-
fill transmission is stopped.
Preamble Count
This bit field selects the amount of preamble repetitions.
Invert Data
This bit enables data inversion between transmit signalling controller
and transmit framer.
0
1
Transmitter On/Off
This bit switches the transmitter of the facility data link to operational (on)
or inoperational state (off).
0
1
Disable CRC
This bit enables CRC generation and transmission on transmission of
HDLC packets.
0
1
PBYTE(7:0)
H
H
Disable data Inversion.
Enable data inversion.
Switch transmitter off.
Switch transmitter on.
Enable CRC generation.
Disable CRC generation.
8
366
7
PCNT(3:0)
4
Register Description
INV
3
XON
2
PEB 3456 E
CRC
DIS
1
05.2001
SF
0

Related parts for peb3456e