peb3456e Infineon Technologies Corporation, peb3456e Datasheet - Page 322

no-image

peb3456e

Manufacturer Part Number
peb3456e
Description
Channelized T3 Termination, With Ds3 Framer, M13 Multiplexer, T1/e1 Framers And 256-channel Hdlc/ppp Controller
Manufacturer
Infineon Technologies Corporation
Datasheet
PEB 3456 E
Register Description
When the error registers are read in response to the “End of
Measurement Interval” interrupt vector , reading this register is not
necessary because the measurement interval would be known.
However the user could assert command TURCOM.RDC to terminate
the measurement interval early and transfer the current bit error count
and bit count to the foreground registers (polling mode).
Data Sheet
322
05.2001