MPC564CZP40 Freescale Semiconductor, MPC564CZP40 Datasheet - Page 711

IC MPU 32BIT W/CODE COMP 388PBGA

MPC564CZP40

Manufacturer Part Number
MPC564CZP40
Description
IC MPU 32BIT W/CODE COMP 388PBGA
Manufacturer
Freescale Semiconductor
Series
MPC5xxr
Datasheets

Specifications of MPC564CZP40

Core Processor
PowerPC
Core Size
32-Bit
Speed
40MHz
Connectivity
CAN, EBI/EMI, SCI, SPI, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
56
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
2.5 V ~ 2.7 V
Data Converters
A/D 32x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
388-BGA
Processor Series
MPC5xx
Core
PowerPC
Data Bus Width
32 bit
Data Ram Size
32 KB
Interface Type
CAN, JTAG, QSPI, SCI, SPI, UART
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
56
Number Of Timers
2
Operating Supply Voltage
0 V to 5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
2 (10 bit, 32 Channel)
For Use With
MPC564EVB - KIT EVAL FOR MPC561/562/563/564
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC564CZP40
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
16.4.5
The remote frame is a message frame that is transmitted to request a data frame. The TouCAN can be
configured to transmit a data frame automatically in response to a remote frame, or to transmit a remote
frame and then wait for the responding data frame to be received.
To transmit a remote frame, a message buffer is initialized as a transmit message buffer with the RTR bit
set to one. Once this remote frame is transmitted successfully, the transmit message buffer automatically
becomes a receive message buffer, with the same ID as the remote frame that was transmitted.
When the TouCAN receives a remote frame, it compares the remote frame ID to the IDs of all transmit
message buffers programmed with a code of 1010. If there is an exact matching ID, the data frame in that
message buffer is transmitted. If the RTR bit in the matching transmit message buffer is set, the TouCAN
transmits a remote frame as a response.
A received remote frame is not stored in a receive message buffer. It is only used to trigger the automatic
transmission of a frame in response. The mask registers are not used in remote frame ID matching. All ID
bits (except RTR) of the incoming received frame must match for the remote frame to trigger a response
transmission.
16.4.6
The TouCAN does not initiate overload frame transmissions unless it detects the following conditions on
the CAN bus:
16.5
The TouCAN module has three special operating modes:
16.5.1
Debug mode is entered when the FRZ1 bit in CANMCR is set and one of the following events occurs:
Once entry into debug mode is requested, the TouCAN waits until an intermission or idle condition exists
on the CAN bus, or until the TouCAN enters the error passive or bus off state. Once one of these conditions
exists, the TouCAN waits for the completion of all internal activity. Once this happens, the following
events occur:
Freescale Semiconductor
A dominant bit is the first or second bit of intermission
A dominant bit is the seventh (last) bit of the end-of-frame (EOF) field in receive frames
A dominant bit is the eighth (last) bit of the error frame delimiter or overload frame delimiter
Debug mode
Low-power stop mode
Auto power save mode
The HALT bit in the CANMCR is set; or
The IMB3 FREEZE line is asserted
Special Operating Modes
Remote Frames
Overload Frames
Debug Mode
MPC561/MPC563 Reference Manual, Rev. 1.2
CAN 2.0B Controller Module
16-17

Related parts for MPC564CZP40