MPC564CZP40 Freescale Semiconductor, MPC564CZP40 Datasheet - Page 592

IC MPU 32BIT W/CODE COMP 388PBGA

MPC564CZP40

Manufacturer Part Number
MPC564CZP40
Description
IC MPU 32BIT W/CODE COMP 388PBGA
Manufacturer
Freescale Semiconductor
Series
MPC5xxr
Datasheets

Specifications of MPC564CZP40

Core Processor
PowerPC
Core Size
32-Bit
Speed
40MHz
Connectivity
CAN, EBI/EMI, SCI, SPI, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
56
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
2.5 V ~ 2.7 V
Data Converters
A/D 32x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
388-BGA
Processor Series
MPC5xx
Core
PowerPC
Data Bus Width
32 bit
Data Ram Size
32 KB
Interface Type
CAN, JTAG, QSPI, SCI, SPI, UART
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
56
Number Of Timers
2
Operating Supply Voltage
0 V to 5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
2 (10 bit, 32 Channel)
For Use With
MPC564EVB - KIT EVAL FOR MPC561/562/563/564
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC564CZP40
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
QADC64E Enhanced Mode Operation
14.4.6
The on-chip periodic/interval timer can be used to generate trigger events at a programmable interval,
initiating execution of queue 1 and/or queue 2. The periodic/interval timer stays reset under the following
conditions:
The following two conditions will cause a pulsed reset of the periodic/interval timer during use:
During the low power stop mode, the periodic timer is held in reset. Since low power stop mode causes
QACR1 and QACR2 to be reset to zero, a valid periodic or interval timer mode must be written after stop
mode is exited to release the timer from reset.
When the IMB3 internal FREEZE line is asserted and a periodic or interval timer mode is selected, the
timer counter is reset after the conversion in progress completes. When the periodic or interval timer mode
has been enabled (the timer is counting), but a trigger event has not been issued, the freeze mode takes
effect immediately, and the timer is held in reset. When the internal FREEZE line is negated, the timer
counter starts counting from the beginning. Refer to
IMB3
14-50
Interface” for more information.
Both queue 1 and queue 2 are programmed to any mode which does not use the periodic/interval
timer
IMB3 system reset or the master reset is asserted
Stop mode is selected
Freeze mode is selected
A queue 1 operating mode change to a mode which uses the periodic/interval timer, even if queue
2 is already using the timer
A queue 2 operating mode change to a mode which uses the periodic/interval timer, provided queue
1 is not in a mode which uses the periodic/interval timer
Roll over of the timer
Periodic/Interval Timer
Example
Number
Interval timer single-scan mode does not use the periodic/interval timer
until the single-scan enable bit is set.
1
2
3
Control Register 0 Information
Frequency
20 MHz
40 MHz
56 MHz
Table 14-22. QADC64E Clock Programmability
MPC561/MPC563 Reference Manual, Rev. 1.2
PRESCALER
0x1B
0x09
0x13
NOTE
Section 14.4.7, “Configuration and Control Using the
QCLK
(MHz)
Input Sample Time (IST) =0
2.0
2.0
2.0
Conversion Time
(µs)
7.0
7.0
7.0
Freescale Semiconductor

Related parts for MPC564CZP40