SPAKDSP303AG100 Freescale Semiconductor, SPAKDSP303AG100 Datasheet - Page 195

no-image

SPAKDSP303AG100

Manufacturer Part Number
SPAKDSP303AG100
Description
IC DSP 24BIT 100MHZ 144-LQFP
Manufacturer
Freescale Semiconductor
Series
DSP563xxr
Type
Fixed Pointr
Datasheets

Specifications of SPAKDSP303AG100

Interface
Host Interface, SSI, SCI
Clock Rate
100MHz
Non-volatile Memory
ROM (576 B)
On-chip Ram
24kB
Voltage - I/o
3.30V
Voltage - Core
3.30V
Operating Temperature
-40°C ~ 100°C
Mounting Type
Surface Mount
Package / Case
144-LQFP
Device Core Size
24b
Clock Freq (max)
100MHz
Mips
100
Device Input Clock Speed
100MHz
Ram Size
24KB
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
144
Package Type
LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SPAKDSP303AG100
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
9.2 Operation
This section discusses the following timer basics:
9.2.1 Timer After Reset
A hardware
Register for each timer, thus configuring each timer as a GPIO. A timer is active only if the timer
enable bit 0 (TCSR[TE]) in the specific timer TCSR is set.
9.2.2 Timer Initialization
To initialize a timer, do the following:
Freescale Semiconductor
1.
2.
Reset
Initialization
Exceptions
Ensure that the timer is not active either by sending a reset or clearing the TCSR[TE]
bit.
Configure the control register (TCSR) to set the timer operating mode. Set the interrupt
enable bits as needed for the application.
RESET
GDB
TIO
Control/Status
Timer Control
CLK/2
Register
signal or software reset instruction clears the Timer Control and Status
Logic
24
9
Prescaler CLK
TCSR
Figure 9-2. Timer Module Block Diagram
2
24
DSP56303 User’s Manual, Rev. 2
Register
Load
24
TLR
Counter
24
Timer interrupt/DMA request
Register
Count
24
TCR
24
24
Compare
Register
=
24
24
TCPR
Operation
9-3

Related parts for SPAKDSP303AG100