Programming in Ladder Form
Advantages of the Insert Mode
3-5-2 Store/Store Insert
Store vs Store Insert
90
Store
Store insert
Item
F3 CR
F4 CR
Key sequence
As the editing operations in the Insert mode simply duplicate those in the Write
mode, they are seldom used. However, as it is not necessary to press the Insert
Key once for each symbol, the Insert mode may be more convenient when con-
secutively inserting a large number of symbols.
These operations are used to write a ladder program created on the screen to
the work disk. Use the Store or Store insert operations before the ladder pro-
gram exceeds 22 lines (the maximum number permitted in a program section).
Ladder programs created on the screen but not saved with the Store or Store
insert operations may be lost when menus are switched, the reset switch is
pressed, or the POWER switch is turned off.
The store operation is used to write a new ladder program section to disk when
editing program sections stored on the work disk. The store insert operation is
Writes the ladder program section created on the screen (with a
maximum of 22 instruction lines) to the work disk.
A message will flash to indicate that the program is being stored.
After the program is stored, the screen will return to the Write
mode and the next address will be displayed.
The addresses of each instruction is fixed when the program is
stored. The addresses will be displayed again the next time the
program is read.
After a program section is read, edited and stored, only the edited
version of the program section is stored on the work disk.
Writes the ladder program section created on the screen (with a
maximum of 22 instruction lines) to the work disk in front of the
previously read program section. The previous program section
remains unchanged on the work disk, behind the new, inserted
program section.
A message will flash to indicate that the program is being stored.
After the program is stored, the screen will return to the Write
mode and the next address will be displayed.