Editing Network Support Tables
Editing Data Link Tables
Checking Data Link Tables
1, 2, 3...
1, 2, 3...
Select “E:Edit data link table” from the SYSMAC NET menu.
A message at the top-right of the screen will indicate that the data link table is
being edited.
The following operation is used to check manually input data link tables.
Node address
Start I/O and DM words,
number of words
1. Follow the sequence below to set the number of nodes in the range from 2 to
2. Move the cursor to the position where data is to be input and enter the data.
3. When all data is input, press the F10 Key to save the data.
1. Select “K:Check data link table” from the SYSMAC NET menu.
2. If continue is displayed at the bottom of the screen, press the PgDn Key to
32:
F1 Key, number_of_link_nodes , Enter Key
Input the node address, I/O start word, number of I/O words, DM start word,
and number of DM words.
A message will indicate if no errors were detected.
An error message table will be displayed if errors are found.
display the next page of error messages. If errors are detected, correct the
data link table and run the check again.
Make sure that the same address is not input twice.
The node address is set on the SYSMAC NET Link Unit.
Press the Insert Key to insert a node address or the
Delete Key to delete a node address.
Set the node address in the range 1 to 126.
Set the I/O and DM start words for the first node only.
The I/O and DM start words for the subsequent nodes
are automatically set after the data is created.
Input Enter, word_address , Enter to input the start word.
Set the number of I/O and DM words in the range 1 to
127.
Set the I/O start and the number of words so that the
last word does not exceed CIO 2555. Set the DM start
and number of words so that the last word does not
exceed D8191 for the CV500 or D24575 for the
DV1000.
Restrict the total number of I/O and DM words to below
3,584 words.
Section 4-6
171
Related parts for C500CP131
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: