C500CP131 Omron, C500CP131 Datasheet - Page 115

no-image

C500CP131

Manufacturer Part Number
C500CP131
Description
C-SERIES SPECIAL I/O UNIT
Manufacturer
Omron
Datasheet

Specifications of C500CP131

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Changing Addresses
Procedure
3-8-3 Changing Words and Bit Address Together
1, 2, 3...
This operation can be used to change all word and bit addresses for specified
words. Changes can be made in the CIO, Auxiliary, and CPU Bus Link Areas
only. Words can be changed to addresses in different data areas.
Multiple, consecutive words can also be changed.
or
1. Select “N:Change data” from the menu.
2. Select “C:Wd adr, DM/EM adr” from the sub-menu.
3. Enter the first address to be changed and press the Enter Key.
4. To change only one word, press the Enter Key.
5. Enter the new word address.
6. Set whether or not bit addresses with I/O names are to be changed.
7. Set whether the I/O comments are to be changed.
8. Select Y at “OK?” and then to execute the change press the Enter Key in
To make multiple changes, enter the last address to be changed.
The start and end word address must be in the same data area, and the end
address must be greater than the start address.
When changing multiple words, enter the new address for the first address.
response to the confirmation message.
A message will flash to indicate that the changes are being made and the
program name will be displayed. The message and program name will be
cleared from the screen when the changes are complete.
Section 3-8
109