C500CP131 Omron, C500CP131 Datasheet - Page 155

no-image

C500CP131

Manufacturer Part Number
C500CP131
Description
C-SERIES SPECIAL I/O UNIT
Manufacturer
Omron
Datasheet

Specifications of C500CP131

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Linking Programs
Error Message Table
Diff I/O names for same address
(address: XXXXXXXX)
Diff address for same I/O name
(I/O name: XXXXXXXX)
Diff I/O comments for same address
(addr: XXXXXXXX)
Dup SFC sheet (sheet #: XXXX)
Dup SFC step (step #: XXXX)
Dup SFC transition (transition#: XXXX)
Dup ladder program (action #: XXXX)
Dup ladder program (transition#: XXXX)
SFC program overflow
Ladder program overflow
I/O name file overflow
I/O comment file overflow
Blk comment file overflow
Message
The I/O name for the displayed I/O
address in a processed file has already
been linked.
Standardized to the I/O name in the file
with the highest priority.
The displayed I/O name in a processed file
has already been linked.
The I/O name is cleared for the I/O
address causing the error.
The I/O comment for the displayed I/O
address in a processed file has already
been linked.
Standardized to the I/O comment in the file
with the highest priority.
The displayed SFC sheet number in a
processed file has already been linked.
The SFC program with the sheet number
causing the error is not linked.
The program with the same sheet number
in the file with the highest priority remains
in the linked program.
The displayed SFC step number in a
processed file has already been linked.
The program with the sheet number
causing the error is not linked.
The displayed SFC transition number in a
processed file has already been linked.
The program with the sheet number
causing the error is not linked.
The program with the displayed action
number in a processed file has already
been linked.
The action program causing the error is not
linked.
The program with the same action number
in the file with the highest priority remains
in the linked program.
The program with the displayed transition
number in a processed file has already
been linked.
The program with the same transition
number in the file with the highest priority
remains in the linked program.
SFC program too large for the work disk.
Ladder program too large for the work disk. The program will be deleted
Too many I/O names registered.
Too many I/O comments registered.
Too many block comments registered or
too many block comments for the work
disk.
Description
The transition program
causing the error will not be
linked.
The link operation is
cancelled and a message will
be displayed at the bottom of
the screen.
from the work disk.
Press the Shift+Esc Keys to
return to the edit screen.
Press the Esc Key to return
to the main menu.
Result
Section 4-3
149