Editing Network Support Tables
Error Message Table
Local Network Error Messages
Relay Network Error Messages
Clearing Routing Tables
Saving Routing Tables
184
Dup local netwk addr
Dup SIOU unit # err
Local netwk addr err
SIOU unit # range err
Too many networks
Dup end netwk addr
End netwk addr range err
Relay netwk addr err
Relay netwk addr rng err
Relay node addr rng err
Too many networks
Error message
Error message
1, 2, 3...
1, 2, 3...
Duplicate network addresses set.
Duplicate unit numbers CPU Bus Units.
A network address is set outside the range 1
to 127.
Unit number of a CPU Bus Unit is set outside
the range 0 to 15.
More than 16 networks are set.
Duplicate network addresses set.
A network address is set outside the range 1
to 127.
The set network address is not set in the
local network table.
A network address is set outside the range 1
to 127.
A node address is set outside the range 1 to
126.
More than 20 networks are set.
Be sure the data disk has been formatted and is not write-protected. Routing
table data cannot be saved if it exceeds the free space available on the data disk.
or
1. Select “C:Clear routing table” from the Routing Table menu.
2. Press the Y and Enter Keys to clear the contents of the routing table.
1. Select “S:Save routing table” from the Routing Table menu.
2. Enter the file name and press the Enter Key.
If errors are detected, correct the routing table and run the check again.
Press the Enter Key to cancel and return to the menu.
A file name input area will be displayed.
To enter an existing file name, press the End Key or Ctrl+M Keys to display
the current file names, select the required file name with the cursor, and
press the Enter Key.
Error description
Error description
Do not set the same network address twice.
Do not set the same unit number for two
CPU Bus Units.
Set the network address within the range 1 to
127.
Set the unit number within the range 0 to 15.
Set no more than 16 networks.
Do not set the same network address twice.
Set the network address within the range 1
to 127.
Only set network addresses already set in
the local network table.
Set the network address within the range 1
to 127.
Set the node address within the range 1 to
126.
Set no more than 20 networks.
Remedy
Remedy
Section 4-6
Related parts for C500CP131
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: