Changing Addresses
3-8
3-8-1 Changing Bit Addresses and TIM/CNT Numbers
Bit adr, T/C no.
Wd adr, DM/EM adr
Wd adr (with bit
adr)
Operation
Changing Addresses
Yes
No
Yes
Bits
I/O, A, G
Note Error messages occurring during the block change operations are displayed af-
No
Yes
Yes
Words
Press the PgDn Key and PgUp Key to display the required instruction block and
the Up and Down Keys to select the required address. The required instruction
blocks can also be displayed with the find operations.
The end address must be equal to or greater than the start address. A single
instruction block is selected if the start address and end address are the same.
The destination address cannot lie between the specified start and end address-
es.
To specify the destination address at the end of the program, display the last in-
struction block, press the PgDn Key so that a message at the top-left of the
screen indicates that the final page is displayed, and then press the Enter Key.
The following operations are used to globally change the bit or word addresses
used in a program on the work disk. The operator can also specify whether the
I/O names and I/O comments are changed. The I/O comments are changed on
the work disk. An operand which cannot be changed is displayed as “????.”
The following three change operations are available, each with different change
capabilities. “Bit adr, T/C no.” can be used to change individual CIO, Auxiliary,
and CPU Bus Link Area bits or individual step and transition numbers.
(Yes: Can be changed, No: Cannot be changed)
ter the block change is complete. If more than two errors occur, only the number
of errors is displayed, without the messages.
With this operation, individual bits in the CIO, Auxiliary, and CPU Bus Link Areas
or individual step or transition numbers can be changed or ranges of timer or
counter numbers can be changed.
In the following example, bit 000003 is changed to timer T0010.
3. Select the required operation.
4. Move the cursor to each address on the screen and press the Enter Key.
Input areas will be displayed at the bottom of the screen for the start, end,
and destination addresses.
T0010
I0000
03
Yes
No
No
instructions
In basic
000003 to T0010
CPM
CPM
(020)
(020)
TIM, CNT
I0000
I0000
No
Yes
No
In advanced
instructions
Areas to be changed
I0001
I0001
Yes
No
No
(numbers)
ST, TN
No
Yes
No
(words, including
indirect addr.)
DM, EM
Section 3-8
TIM, CNT
All
All
Setting
range
103