C500CP131 Omron, C500CP131 Datasheet - Page 122

no-image

C500CP131

Manufacturer Part Number
C500CP131
Description
C-SERIES SPECIAL I/O UNIT
Manufacturer
Omron
Datasheet

Specifications of C500CP131

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Programming in the Mnemonic Display Mode
Examples of Entering Instructions
Correcting Input
116
Note Always use the check program operation; no program errors will be detected if
It is not necessary to input leading zeros for bit or word addresses. Input address
00000 may be input as 0.
Press the Space Key to separate the prefix from the bit address.
To input the differentiate up variation of an instruction, enter the instruction and
then press the Shift+F3 Keys.
To input the differentiate down variation of an instruction, enter the instruction
and then press the Shift+F4 Keys.
To input the immediate refresh variation of an instruction, enter the instruction
and then press the Shift+F10 Keys.
To input the differentiate up/down and immediate variation of an instruction, en-
ter the instruction and then press Shift+F3 Keys or Shift+F4 Keys followed by the
Shift+F10 Keys
Use the following keys to edit previously input characters.
the mnemonic program is incorrect.
Auxiliary Area
CIO Area
CPU Bus Link Area
Constants
Counter Area
Data registers
DM Area
EM Area
Index registers
Indirectly addressed DM Area
Indirectly addressed EM Area
Step Area
Timer Area
Transition Area
L D _ 2 0 1 CR
O R _ N O T _ T 2 4 CR
T I M _ 1 _ # 1 0 0 CR
M O V _ A 1 _ 5 CR
M O V Shift+F3 _ 1 0 _ 6 CR
S E T Shift+F4 Shift+F10 _ 1 CR
Cursor
Backspace
Del
Ins
Shift+Home
Key
Area
Input
Move the cursor left and right along the input area.
Deletes the character to the left of the cursor.
Deletes the character at the cursor position.
Inserts a space at the cursor position.
Deletes all displayed instructions.
Key(s)
A
None
G
#
C
DR
D
E
IR
ST
T
TN
D
E
LD 000201
OR NOT T0024
TIM 0001 #0100
MOV(030) A001 0005
jMOV(030) 0010 0006
!iSET(016) 000001
Function
Operation
Section 3-10

Related parts for C500CP131