Select the required setting with the cursor and press the Enter Key.
Select the required setting with the cursor and press the Enter Key.
Max.
step/transitions
Max. actions
Space for SFC
online edt
Protect
2. Select the PC model for the UM conversion. A setting screen will be dis-
3. To change a default setting, select the item to be changed with the cursor
4. When the settings are complete, move the cursor to OK and press the Enter
played to set the conversion conditions. If SFC programming is not being
used, only “P:Protect” will be displayed.
and change the setting.
The functions and settings are shown in the following table.
Key.
Item
The ladder program area can be expanded by restricting the
maximum number of steps and transitions.
Select the upper limit from the following values:
CV500-CPU01-E:
CV1000/CV2000-CPU01-E: Standard, 256, 512, 1024
The default setting is Standard. This sets the maximum number
of steps/transitions for the PC model.
The ladder program area can be expanded by restricting the
maximum number of actions.
Select the upper limit from the following values:
CV500-CPU01-E:
CV1000/CV2000-CPU01-E: Standard, 512, 1024, 2048
The default setting is Standard. This sets the maximum number
of actions for the PC model.
The default setting is No, which stores SFC programs and
ladder programs consecutively in the PC. If a space is set, the
set amount of space is left between SFC and ladder programs
stored in the PC.
Setting the space for the SFC online editing reduces the time to
append SFC programs with the online editing operations
because it is not necessary to change the ladder program area.
The default setting is No, so that programs are not protected. If
a protected program is transferred to the PC, it cannot
subsequently be read or changed (including re-transfer to the
computer) outside the PC. The protection can be set to cover
the entire program or part of the program (by selecting up to 3
sheet, action, or transition numbers).
Ladder Only
Function and Setting
Standard, 256, 512
Standard, 512, 1024
Section 6-3
209