PC Setup
7-2-1 PC System Setup
222
PC Setup Overview
Letter
A
B
C
Hold
areas
Startup
hold
Startup mode
Hold area
Hold Racks (Hold bits) To specify Racks or Masters
Forced Status Hold Bit
status (A00013)
(Forced status)
IOM Hold Bit (A00012)
status (I/O bits)
Restart Continuation
Bit status (A00011)
(Power on flag)
Name
The use of each operation on this menu is described below.
To change any of the parameters in the PC Setup on the work disk, select “A:PC
setup” from the first PC Setup menu. The following list of parameters will appear.
Any of the above parameters can be changed by selecting it from the list and
inputting data according to the displays that will appear. The displays that ap-
pear when each parameter is selected are described beginning on page 229 af-
ter the following tables.
The following tables list the parameters in the PC Setup, provide examples of
normal application, and provides the default values.
PC setup
Save PC settings
Retrieve PC settings
Clear PC settings
Menu item
To specify which bits are to
maintain status when power is
turned off.
(Remote I/O Subsystems) that are
to maintain status when operation
is stopped or modes are changed.
To maintain the status of the
Forced Status Hold Bit when power
is turned off and on.
To maintain the status of the IOM
Hold Bit when power is turned off
and on.
To maintain the status of the
Restart Continuation Bit when
power is turned off and on.
To specify the initial PC operating
mode.
Sets or changes the PC Setup on the work disk.
Saves the PC system setup data on the work disk
to a data disk or the hard disk.
Reads the PC Setup data from a data disk or the
hard disk and saves it to the work disk.
Sets all parameters in the PC Setup on the work
disk to their default values.
Function
Function
To extent the Holding Area beyond
CIO 300.
To maintain output status for
specific Racks or Remote I/O
Subsystems.
To maintain the status of bits forced
ON or OFF.
To prevent I/O status from being
cleared when power is turned on.
These parameters must be set to
YES when using restart
continuation.
To automatically start the PC when
power is turned ON. Set the mode
to MONITOR or RUN when using
restart continuation.
Normal application(s)