C500CP131 Omron, C500CP131 Datasheet - Page 85

no-image

C500CP131

Manufacturer Part Number
C500CP131
Description
C-SERIES SPECIAL I/O UNIT
Manufacturer
Omron
Datasheet

Specifications of C500CP131

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Programming in Ladder Form
Bit/Word Addresses and Data
OUT
OUT NOT
TIMER
COUNTER
Advanced
instruction
Immediate update
instructions
Differentiate up
instructions
Differentiate down
instructions
Instruction
Symbol
Note The second of each pair of carriage returns is not required when inputting the
CNT
TIM
–––
!
j
i
Refer to the table of advanced instructions for details about function codes. Re-
fer to CV500/CV1000 Operation Manual: Ladder Diagrams for information on
the operands for each instruction.
In the following table, items in parentheses are not required when inputting the
program in C mode, but are required when inputting in CV mode.
program in C mode, but is required when inputting in CV mode.
Data area prefixes may be input as either upper- or lower-case characters. If an
incorrect number is entered, press the Home Key and re-enter the value. It is not
necessary to input leading zeros for addresses or SVs.
I and Q are displayed only after an I/O table is registered.
F9 Bit_address CR
Shift+F9 Bit_address
CR
Shift+F5 Timer_number
CR (CR) # SV CR
or
Shift+F5 Timer_number
CR (CR) Word_address
CR
Shift+F6
Counter_number CR
(CR) # SV CR
or
Shift+F6
Counter_number CR
(CR) Word_address CR
F10 Function_code CR
(CR) Operand CR (CR)
Operand CR (CR)
Operand CR
OUT/OUT NOT:
Instruction Bit_address
Shift+F10 CR
Advanced instruction:
Instruction Shift+F10
CR (CR) ( Operand CR
(CR)) Operand CR
Instruction Shift+F3 CR
(CR) ( Operand CR (CR))
Operand CR
Instruction Shift+F4 CR
(CR) ( Operand CR (CR))
Operand CR
Function key inputs
O U T _ Bit_address CR
O U T _ N O T _
Bit_address CR
T I M _ Timer_number _
# SV CR
or
T I M _ Timer_number _
Word_address CR
C N T _
Counter_number _ # SV
CR
or
C N T _
Counter_number _
Word_address CR
Instruction _ Operand _
Operand _ Operand CR
Instruction _ ( Operand
_) Operand Shift+F10
CR
Instruction _ ( Operand
_) Operand Shift+F3 CR
Instruction _ Operand
Shift+F4 CR
Mnemonic inputs
–––
OR NOT can also be
input using the Slash (/)
Key: F9 / Bit_address
CR.
To enter a constant as
the SV, input #SV.
To set the SV from a
word, enter the word
address only.
–––
Input leading zeros for
the function code. The
number of operands
varies according to the
instruction.
Applicable only to OUT,
OUT NOT, KEEP(011),
DIFU(013), DIFD(014),
SET(016), RSET(017),
CMP(020), and
MOV(030).
–––
Applicable only to
SET(016) and
RSET(017) only
Remarks
Section 3-5
79