Editing Network Support Tables
Editing Relay Network Tables
Checking Routing Tables
1, 2, 3...
Set the items shown in the following table. Use the Up, Down, Left, Right Keys to
move the cursor to the required positions on the screen.
Press the PgUp Key to return to the local network table editing screen.
The following operation is used to check routing tables.
End Netwk
Relay network, node
1. Select “K:Check routing table” from the Routing Table menu.
2. If continue is displayed at the bottom of the screen, press the PgDn Key to
A message will indicate if no errors were detected. An error message table
will be displayed if errors are found.
display the next page of error messages.
Item
Set each end network address for network relay
communication. Set the network addresses in the range
1 to 127. Do not set the same address twice.
Press the Insert Key to insert a network address or the
Delete Key to delete a network address.
Set the network and node addresses of the first node
that must be passed through to reach the destination
network. Set the network addresses in the range 1 to
127. Only set networks that are in the local network
table.
The network and node addresses can also be set using
PC ID. Move the cursor to the PC ID column and input
the Enter Key, PC_name , and Enter Key.
Press the End Key or Ctrl+M Keys to display PC IDs.
Select the required PC ID from the table with the cursor
and press the Enter Key. The network address and node
address will automatically be displayed when the PC ID
is input.
Setting method
Section 4-6
183