Editing Network Support Tables
Parameter Ranges
Checking Data Link Tables
I/O (CIO) link words
DM link words
I/O (CIO) start word and end word (start word
plus number of words)
DM start word and end word (start word plus
number of words)
Status start word and end word (start word plus
number of words)
Parameter
1, 2, 3...
Set the items shown in the following table for each enabled node. Use the Up,
Down, Left, Right Keys to move the cursor to the required position on the screen.
The following operation is used to check manually created data link tables.
PC
Refresh wd
Status wd
Node
1. Select “K:Check data link table” from the SYSMAC LINK menu to start the
check.
A message will indicate if no errors were detected.
An error message table will be displayed if errors are found.
Item
0 to 254
0 to 254
0000 to 2555
D00000 to D08191
---
CV500-CPU01-E
CVM1-CPU01-E
Set the PC series of the node.
Press the 1 Key for CV-series PC and the 2 Key for other PC and
then press the Enter Key.
Set the first data link word for the displayed node in the CIO (IR)
or DM Area.
Input the Enter Key, word_address , Enter Key.
This setting is not required for CV-series PCs. The word is
allocated CIO 1500.
For C-series PCs, set the first word of the data link status area.
Input the Enter Key, word_address , Enter Key.
The node displayed at the top is the node for which the data link
is being set. Be sure you are setting data for the correct node.
Only set nodes previously set in the common link parameters.
Words set for the current node (i.e., the node displayed at the top)
are written by the current node and are transferred to the other
nodes. Words set for other nodes are written by the other nodes
and received by the current node.
I/O words and DM words set in the common link parameters will
be automatically displayed.
The data link area will be allocated from the first refresh words set
in the table in order of the numbers at the left of the table.
Press the Insert Key to insert a node or the Delete Key to delete a
node.
D00000 to D24575
CV1000-CPU01-E
CV2000-CPU01-E
CVM1-CPU11-E
Setting method
PC
0 to 64
0 to 254
1000 to 1063
D00000 to D04095
0000 to 0252
1000 to 1191
D00000 to D04095
Other
Section 4-6
177
Related parts for C500CP131
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: