Editing the I/O Table
4-5-2 Checking I/O Tables
Error Messages
1, 2, 3...
Refer to the table on page 167 for information on the error messages.
The following operation is used to check the I/O table on the work disk and dis-
play any errors found. Conduct this check when transferring an I/O table created
via the PC to the computer.
This check is conducted automatically if the I/O table is written using the Write
I/O table operation.
If an error is detected when the I/O table is checked, one of the error messages
below will appear in the error message table. Take the following measures to
correct the error:
3. When all required allocations have been entered, press the Shift+F10 Keys
4. Press the Esc Key to return to the original screen. Correct the errors and
1. Select “K:Check I/O table” from the I/O Table menu. The contents of the I/O
2. Press the PgDn to scroll down the pages of the error message table and the
3. Change the I/O table to match the actual units connected using the Create
Do not mix inputs and outputs within the same word.
The I/O Link Units are set in units of 16 points; enter two symbols for 8 points
in the same word.
The “16-point input/16-point output” setting is not used when an I/O Link Unit
is connected to a CV-series PC.
to return to the Basic Rack screen then press the Shift+F10 and Enter Keys
to check and save the settings. The set values will be lost if the Shift+F10
and Enter Keys are not pressed from the Basic Rack screen.
An error message table will be displayed if any errors are discovered in the
I/O table settings after the Shift+F10 and Enter Keys are pressed. The errors
are displayed on separate pages of the error message table for the BASIC
Units, SYSMAC BUS Slaves, Group-1/2/3 Slaves, I/O Terminals, and CPU
Bus Unit. Press the PgDn to scroll down the error message table and the
PgUp Key to return to the previous page. The errors for the I/O Terminal are
the last page of the error message table.
press the Shift+F10 Keys again.
table will be checked and a message will be displayed if an errors are de-
tected.
The errors are displayed on separate pages of the error message table for
the BASIC Units, SYSMAC BUS Slaves, Group-1/2/3 Slaves, I/O Terminals,
and CPU Bus Unit.
PgUp Key to return to the previous page. Refer to the following table for in-
formation on the error messages.
I/O table operations.
If the table was written via CVSS:
Press the Esc Key to return to the previous screen and edit the I/O table.
If the table was generated via the PC:
Change the I/O table to match the actual units connected, using the Create
I/O table operations.
Section 4-5
167