Specifications of C500CP131

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
System Setup
Binary
ASCII
1, 2, 3...
The following communications parameters appear when Binary is selected. The
parameters determine the settings that will be used when communicating be-
tween the PC and the computer. These settings are for the computer and must
agree with the settings for the PC (see the following).
To change a parameter, select the item and then specify the desired settings on
the display that will appear. The parameters and their possible settings are de-
scribed in the following table.
Follow the procedures mentioned below to connect the tool bus port on the PC’s
CPU and the computer.
The following communications parameters appear when ASCII is selected. The
parameters determine the settings that will be used when communicating be-
Port
Baud rate
Comm watch
time
1. Set the baud rate (19.2 kbps, 9,600 bps, or 4,800 bps) with DIP switches on
2. Connect the CV500-CIF01 cable to the computer.
3. Select Binary from the offline system setup menu and set the communica-
4. Connect the CV500-CIF01 cable to the tool bus port on the PC’s CPU.
5. Press the Shift+F1 Keys on the offline system setup menu to allow the PC to
Parameter
the front of the PC’s CPU for tool bus communication.
tions mode to 1.
communicate online with the computer.
The computer port to which the PC is
connected.
The transmission speed.
The monitoring time for responses
from the PC. An error will be
generated if the PC does not respond
within the specified time.
Function
,
COM1 or COM2
Set to the value that has
been set with the DIP
switches on the front of
the PC’s CPU.
2 to 60 s
Possible settings
Section 7-1
219