Specifications of C500CP131

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
PC Data Areas
12
SYSMAC
BUS Area
Temporary
Relay Area
CPU Bus
Link Area
Auxiliary
Area
Transition
Area
Step Area
Timer Area
Counter
Area
DM Area
EM Area
Index
registers
Data
registers
Area
CV500-CPU01-E
CVM1-CPU01-E
CV1000-CPU01-E
CV2000-CPU01-E
CVM1-CPU11-E
All
All
All
CV500-CPU01-E
CV1000-CPU01-E
CV2000-CPU01-E
CV500-CPU01-E
CV1000-CPU01-E
CV2000-CPU01-E
CV500-CPU01-E
CVM1-CPU01-E
CV1000-CPU01-E
CV2000-CPU01-E
CVM1-CPU11-E
CV500-CPU01-E
CVM1-CPU01-E
CV1000-CPU01-E
CV2000-CPU01-E
CVM1-CPU11-E
CV500-CPU01-E
CVM1-CPU01-E
CV1000-CPU01-E
CV2000-CPU01-E
CVM1-CPU11-E
CV1000-CPU01-E
CV2000-CPU01-E
All
All
PC
Words: CIO 2300 to CIO 2427
Bits:
($08FC to $097B)
Words: CIO 2300 to CIO 2555
Bits:
($08FC to $09FB)
TR0 to TR7 (bits only)
($09FF)
Words: G000 to G255
Bits:
($0A00 to $0AFF)
Words: A000 to A511
Bits:
($0B00 to $0CFF)
TN0000 to TN0511
($0D00 to $0D1F)
TN0000 to TN1023
($0D00 to $0D3F)
ST0000 to ST0511
($0E00 to $0E1F)
ST0000 to ST1023
($0E00 to $0E3F)
T0000 to T0511
(Completion Flags: $0F00 to $0F1F
Present Values:
T0000 to T1023
(Completion Flags: $0F00 to $0F3F
Present Values:
C0000 to C0511
(Completion Flags: $0F80 to $0F9F
Present Values:
C0000 to C1023
(Completion Flags: $0F80 to $0FBF
Present Values:
D00000 to D08191
($2000 to $3FFF)
D00000 to D24575
($2000 to $7FFF)
E00000 to E32765 for each bank; 2,
4, or 8 banks
($8000 to $8FFD)
IR0 to IR2
DR0 to DR2
CIO 230000 to CIO 242715
CIO 230000 to CIO 255515
G00000 to G25515
A00000 to A51115
Range
$1000 to $13FF)
$1800 to $19FF)
$1800 to $1BFF)
$1000 to $11FF)
These bits are used for remote I/O points in
the SYSMAC BUS Remote I/O System
unless the default allocations are changed in
the PC Setup.
Bits not used to control I/O points can be
used as work bits. Up to word 2399 can be
set as holding bits via the PC Setup.
Used to temporarily store execution
conditions. TR bits are not input when
programming directly in ladder diagrams.
G000 is the PC Status Area; G001 to G004,
the Clock Area. G008 to G127 contain PC
output bits; G128 to G255, CPU Bus Unit
output bits.
Contains flags and bits with special
functions.
Transition Flags for the transitions in the
SFC program.
Step Flags for the steps in the SFC program.
A step is active when its flag is ON.
Used to define timers (normal, high-speed,
and totalizing) and to access Completion
Flags, PV, and SV.
Used to define counters (normal, reversible,
and transition) and to access Completion
Flags, PV, and SV.
Used for internal data storage and
manipulation.
EM functions just like DM. An Extended Data
Memory Unit must be installed.
Used for indirect addressing.
Generally used for indirect addressing.
Function
Section 1-3