Editing the I/O Table
4-5-3 Saving I/O Tables
168
Error message
# error
Dup unit #
Dup word
Excess units
High address
High total
words
IN/OUT mix
Intr unit posi err An Interrupt Input Unit has been allocated to
Undefined RM
\
The total number of I/O points exceeds the limit.
Duplicate unit numbers for CPU Bus Units.
Duplicate word allocations.
The total number of Units exceeds the prescribed
limit.
An address is set out of range.
The total number of words exceeds the limit.
Both inputs and outputs used in the same word of
a I/O Terminal.
Rack other than the CPU Rack (rack #0) or
Expansion CPU Rack (rack #1).
Master not recognized by the CPU.
1, 2, 3...
Note Enter the file name as up to 8 characters. Lower-case characters are converted
Error description
Insert a data disk into the drive. It is recommended that the user program and I/O
table be written as a set to the same data disk.
Be sure the data disk has been formatted and is not write-protected. I/O table
data cannot be saved if it exceeds the free space available on the data disk.
The following display will appear when “S:Save I/O table” is selected from the
Edit I/O Table menu.
to upper-case. A single directory name can have up to 8 characters with a total of
1. Enter the file name and press the Enter Key.
2. If the input file name already exists, a message will ask if the file should be
3. Input the title and press the Enter Key.
4. Press the Enter Key to save the I/O table data. The I/O table editing screen
To enter an existing file name, press the End Key or Ctrl+M Keys to display
the current file names, select the required file name with the cursor, and
press the Enter Key.
overwritten. Press the Y and Enter Keys to overwrite the file, or press the
Enter Key to cancel and input a new file name.
The title input area will appear when the Enter Key is pressed.
The title can be up to 30 characters long.
will be displayed after the data is saved.
The settings made in the PC Setup from the Edit I/O Table menu are saved
simultaneously.
Change settings to bring the total number of I/O
points below the limit.
Change settings so that the same unit number is
not used twice.
Change settings so that the same word is not
allocated twice.
Change settings to bring the total number of Units
below the limit.
Change the settings to bring all addresses within
the prescribed ranges.
Change settings to bring the total number of
words below the limit.
Change the settings so that only inputs or only
outputs are used in a single words.
Move the Interrupt Input Unit to the CPU Rack or
Expansion CPU Rack.
Set the Expansion CPU Rack to rack #1.
Correct the I/O table.
Remedy
Section 4-5