HD6412240 RENESAS [Renesas Technology Corp], HD6412240 Datasheet - Page 555

no-image

HD6412240

Manufacturer Part Number
HD6412240
Description
Renesas 16-Bit Single-Chip Microcomputer H8S Family / H8S/2200 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6412240FA13
Manufacturer:
HITACHI
Quantity:
8 831
Part Number:
HD6412240FA13V
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412240FA20
Manufacturer:
HITACHI
Quantity:
12 388
Part Number:
HD6412240FA20V
Manufacturer:
LT
Quantity:
3 220
Part Number:
HD6412240FA20V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6412240TE13
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6412240TE13
Quantity:
33
Part Number:
HD6412240TE13V
Manufacturer:
RENESAS
Quantity:
15 090
Part Number:
HD6412240TE13V
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6412240TE13V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
14.4
The A/D converter operates by successive approximation with 10-bit resolution. It has two
operating modes: single mode and scan mode.
14.4.1
Single mode is selected when A/D conversion is to be performed on a single channel only. A/D
conversion is started when the ADST bit is set to 1, according to the software or external trigger
input. The ADST bit remains set to 1 during A/D conversion, and is automatically cleared to 0
when conversion ends.
On completion of conversion, the ADF flag is set to 1. If the ADIE bit is set to 1 at this time, an
ADI interrupt request is generated. The ADF flag is cleared by writing 0 after reading ADCSR.
When the operating mode or analog input channel must be changed during analog conversion, to
prevent incorrect operation, first clear the ADST bit to 0 in ADCSR to halt A/D conversion. After
making the necessary changes, set the ADST bit to 1 to start A/D conversion again. The ADST bit
can be set at the same time as the operating mode or input channel is changed.
Typical operations when channel 1 (AN1) is selected in single mode are described next. Figure
14.3 shows a timing diagram for this example.
[1] Single mode is selected (SCAN = 0), input channel AN1 is selected (CH1 = 0, CH0 = 1), the
[2] When A/D conversion is completed, the result is transferred to ADDRB. At the same time the
[3] Since ADF = 1 and ADIE = 1, an ADI interrupt is requested.
[4] The A/D interrupt handling routine starts.
[5] The routine reads ADCSR, then writes 0 to the ADF flag.
[6] The routine reads and processes the connection result (ADDRB).
[7] Execution of the A/D interrupt handling routine ends. After that, if the ADST bit is set to 1,
A/D interrupt is enabled (ADIE = 1), and A/D conversion is started (ADST = 1).
ADF flag is set to 1, the ADST bit is cleared to 0, and the A/D converter becomes idle.
A/D conversion starts again and steps [2] to [7] are repeated.