HD6412240 RENESAS [Renesas Technology Corp], HD6412240 Datasheet - Page 536

no-image

HD6412240

Manufacturer Part Number
HD6412240
Description
Renesas 16-Bit Single-Chip Microcomputer H8S Family / H8S/2200 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6412240FA13
Manufacturer:
HITACHI
Quantity:
8 831
Part Number:
HD6412240FA13V
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412240FA20
Manufacturer:
HITACHI
Quantity:
12 388
Part Number:
HD6412240FA20V
Manufacturer:
LT
Quantity:
3 220
Part Number:
HD6412240FA20V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6412240TE13
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6412240TE13
Quantity:
33
Part Number:
HD6412240TE13V
Manufacturer:
RENESAS
Quantity:
15 090
Part Number:
HD6412240TE13V
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6412240TE13V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 13 Smart Card Interface
Serial Data Reception
Data reception in Smart Card mode uses the same processing procedure as for the normal SCI.
Figure 13.7 shows an example of the transmission processing flow.
[1] Perform Smart Card interface mode initialization as described above in Initialization.
[2] Check that the ORER flag and PER flag in SSR are cleared to 0. If either is set, perform the
[3] Repeat steps [2] and [3] until it can be confirmed that the RDRF flag is set to 1.
[4] Read the receive data from RDR.
[5] When receiving data continuously, clear the RDRF flag to 0 and go back to step [2].
[6] To end reception, clear the RE bit to 0.
With the above processing, interrupt servicing or data transfer by the or DTC is possible.
Rev.3.00 Mar. 26, 2007 Page 494 of 772
REJ09B0355-0300
appropriate receive error processing, then clear both the ORER and the PER flag to 0.
No
No
Figure 13.7 Example of Reception Processing Flow
RDRF flag in SSR to 0
Read RDR and clear
All data received?
Clear RE bit to 0
ORER = 0 and
Start reception
Initialization
RDRF = 1?
PER = 0?
Start
Yes
Yes
Yes
No
Error processing