EP2AGX190FF35C6N Altera, EP2AGX190FF35C6N Datasheet - Page 360

no-image

EP2AGX190FF35C6N

Manufacturer Part Number
EP2AGX190FF35C6N
Description
IC ARRIA II GX 190K 1152FBGA
Manufacturer
Altera
Series
Arria II GXr

Specifications of EP2AGX190FF35C6N

Number Of Logic Elements/cells
181165
Number Of Labs/clbs
7612
Total Ram Bits
9939
Number Of I /o
612
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-FBGA
Family Name
Arria® II GX
Number Of Logic Blocks/elements
190300
# I/os (max)
612
Frequency (max)
400MHz
Operating Supply Voltage (typ)
900mV
Logic Cells
190300
Ram Bits
10380902.4
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
1152
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2AGX190FF35C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2AGX190FF35C6N
Manufacturer:
ALTERA
0
Part Number:
EP2AGX190FF35C6N
0
10–10
Recovering From CRC Errors
Document Revision History
Table 10–9. Document Revision History
Arria II Device Handbook Volume 1: Device Interfaces and Integration
December 2010
July 2010
November 2009
February 2009
Date
The system that the Arria II device resides in must control device reconfiguration.
After detecting an error on the CRC_ERROR pin, strobing the nCONFIG signal low directs
the system to perform the reconfiguration at a time when it is safe for the system to
reconfigure the device.
When the data bit is rewritten with the correct value by reconfiguring the device, the
device functions correctly.
While soft errors are uncommon in Altera
applications require a design to account for these errors.
Table 10–9
Version
4.0
3.0
2.0
1.0
lists the revision history for this chapter.
Updated for Arria II GX v10.0 release:
Updated for Arria II GX v9.1 release:
Initial release.
Updated for the Quartus II software version 10.1 release.
Added Arria II GZ devices information.
Minor text edits.
Updated Table 10–3, Table 10–6, Table 10–7, and Table 10–8.
Updated Table 10–7 and Table 10–8.
Minor text edits.
®
devices, certain high-reliability
Changes
Chapter 10: SEU Mitigation in Arria II Devices
December 2010 Altera Corporation
Recovering From CRC Errors

Related parts for EP2AGX190FF35C6N