DF2317VTE25 Renesas Electronics America, DF2317VTE25 Datasheet - Page 512

MCU 3V 128K 100-TQFP

DF2317VTE25

Manufacturer Part Number
DF2317VTE25
Description
MCU 3V 128K 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheet

Specifications of DF2317VTE25

Core Processor
H8S/2000
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
79
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Other names
HD64F2317VTE25
HD64F2317VTE25

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2317VTE25V
Manufacturer:
AD
Quantity:
3 643
Part Number:
DF2317VTE25V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 12 Serial Communication Interface (SCI)
Rev.7.00 Feb. 14, 2007 page 478 of 1108
REJ09B0089-0700
No
No
No
Figure 12.12 Sample Multiprocessor Serial Reception Flowchart
Read ORER and FER flags in SSR
Read ORER and FER flags in SSR
Read receive data in RDR
Read receive data in RDR
Read RDRF flag in SSR
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Read MPIE bit in SCR
FER ∨ ORER = 1?
FER ∨ ORER = 1?
All data received?
Start of reception
This station's ID?
Initialization
RDRF = 1?
RDRF = 1?
<End>
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
[4]
[3]
[1]
[2]
Error handling
(Continued on
next page)
[5]
[1]
[2]
[3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
ID reception cycle:
Set the MPIE bit in SCR to 1.
SCI status check, ID reception
and comparison:
Read SSR and check that the
RDRF flag is set to 1, then read
the receive data in RDR and
compare it with this station's ID.
If the data is not this stationÕs
ID, set the MPIE bit to 1 again,
and clear the RDRF flag to 0.
If the data is this station's ID,
clear the RDRF flag to 0.
SCI status check and data
reception:
Read SSR and check that the
RDRF flag is set to 1, then read
the data in RDR.
Receive error handling and break
detection:
If a receive error occurs, read the
ORER and FER flags in SSR to
identify the error. After
performing the appropriate error
handling, ensure that the ORER
and FER flags are both cleared
to 0.
Reception cannot be resumed if
either of these flags is set to 1.
In the case of a framing error, a
break can be detected by reading
the RxD pin value.

Related parts for DF2317VTE25