PEB22554 SIEMENS [Siemens Semiconductor Group], PEB22554 Datasheet - Page 76

no-image

PEB22554

Manufacturer Part Number
PEB22554
Description
ICs for Communications
Manufacturer
SIEMENS [Siemens Semiconductor Group]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB22554H/T
Manufacturer:
INF
Quantity:
5 510
Part Number:
PEB22554H/T
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
PEB22554HT
Manufacturer:
INFINEON
Quantity:
325
Part Number:
PEB22554HT V1.3
Quantity:
1 078
Part Number:
PEB22554HT V1.3
Manufacturer:
Infineon
Quantity:
490
Part Number:
PEB22554HT2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB22554HTV1.3
Manufacturer:
INFIEON
Quantity:
20 000
Part Number:
PEB22554HTV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB22554V1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Table 8
Summary of Alarm Detection and Release
Alarm
Semiconductor Group
Loss of Signal
(LOS)
Alarm Indication
Signal (AIS)
Remote Alarm
(RRA)
Remote Alarm in
Time-Slot 16
(TS16RA)
Loss of Signal in
Time-Slot 16
(TS16LOS)
Alarm Indication
Signal in Time-Slot 16
(TS16AIS)
Transmit Line Short
(XLS)
Transmit Ones
Density
(XLO)
Detection Condition
no transitions (logical
zeros) in a programmable
time interval of 16 - 4096
consecutive pulse periods.
Programmable receive
input signal threshold
FMR0.ALM = 0:
less than 3 zeros in
250 µsec and loss of frame
alignment declared
FMR0.ALM = 1:
less than 3 zeros in
each of two consecutive
250 µsec periods
bit 3 = 1 in time-slot 0 not
containing the FAS word
Y-bit = 1 received in CAS
multiframe alignment word
all zeros for at least 16
consecutively received
time-slots 16
time-slot 16 containing less
than 4 zeros in each of two
consecutive CAS
multiframes periods
more than 32 pulse periods
with highly increased
transmit line current on
XL1/2
32 consecutive zeros in the
transmit data stream on
XL1/2
76
Clear Condition
programmble number of ones
(1-256) in a programmable time
interval of 16 - 4096 consecutive
pulse periods. A one is a signal
with a level above the
programmed threshold.
FMR0.ALM = 0:
more than 2 zeros in
250 µsec
FMR0.ALM = 1:
more than 2 zeros in each of two
500 µsec periods
set conditions no longer detected.
Y-bit = 0 received in CAS
multiframe alignment word
receiving a one in
time-slot 16
time-slot 16 containing more than
3 zeros in each of two
consecutive CAS multiframes
periods
no transmit line current limiter
active
Cleared with each transmitted
pulse
Functional Description E1
PEB 22554
09.98

Related parts for PEB22554