R5F61662N50FPV Renesas Electronics America, R5F61662N50FPV Datasheet - Page 764

MCU 24KB FLASH 384K 144-LQFP

R5F61662N50FPV

Manufacturer Part Number
R5F61662N50FPV
Description
MCU 24KB FLASH 384K 144-LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8SX/1600r
Datasheet

Specifications of R5F61662N50FPV

Core Processor
H8SX
Core Size
16/32-Bit
Speed
50MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, SmartCard, USB
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
92
Program Memory Size
384KB (384K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R5F61662N50FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 18 A/D Converter
18.7.4
When the A/D start bit (ADST) is cleared during A/D conversion by software, A/D conversion
results may be stored incorrectly (ADDR), or when A/D conversion restarts, the interrupt flag may
be misset.
To avoid these events, follow the steps below.
(1)
As the ADST bit is automatically cleared when A/D conversion is completed, do not clear the
ADST bit by software during A/D conversion.
(2)
• When the A/D converter is activated by software
Rev. 2.00 Sep. 16, 2009 Page 734 of 1036
REJ09B0414-0200
Do not clear the ADST bit by software during A/D conversion. To stop A/D conversion,
rewrite the SCANE bit to change modes from scan mode to single mode. By rewriting the
SCANE bit, the A/D converter is stopped without clearing the ADST bit by software.
However, after rewriting the SCANE bit, it may take up to 1.5-channel A/D conversion time to
stop A/D conversion and set the A/D end flag (ADF) to 1. Moreover, the ADDR value after
A/D conversion is completed should not be used.
For detailed settings, see figure 18.10.
In Single Mode or Scan Mode (One-Cycle Scan Mode)
In Scan Mode (Continuous Scan Mode)
Notes on Stopping the A/D Converter

Related parts for R5F61662N50FPV