TMP92xy22FG Toshiba, TMP92xy22FG Datasheet - Page 198

no-image

TMP92xy22FG

Manufacturer Part Number
TMP92xy22FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP92xy22FG

Package
LQFP100
Rom Types(m=mask,p=otp, F=flash,e=eeprom)
Romless
Rom Combinations
Romless
Ram Combinations
32
Architecture
32-bit CISC
Usb/spi Channels
-
Uart/sio Channels
2
I2c/sio Bus Channels
1
(s)dram Controller
-
Adc 10-bit Channel
8
Da Converter
-
Timer 8-bit Channel
4
Timer 16-bit Channel
2
Pwm 8-bit Channels
-
Pwm 16-bit Channels
-
Cs/wait Controller
4
Dual Clock
-
Number Of I/o Ports
50
Power Supply Voltage(v)
3.0 to 3.6
Note: When the transfer mode is changed, the contents of the SBI0DBR will be lost. If the mode
2.
must be changed, conclude data receiving by clearing the <SIOS> to “0”, read the last data,
then change the mode.
Figure 3.10.26 Transmission Data Hold Time at End Transmit
8-bit receive mode
switching to receive mode. Data is received into the shift register via the SI pin
and synchronized with the serial clock, starting from the least significant bit
(LSB). When the 8-bit data is received, the data is transferred from the shift
register to the SBI0DBR. The INTSBE0 (Buffer full) interrupt request is
generated to request that the received data be read. The data is then read from
the SBI0DBR by the interrupt service program.
wait function will be in effect until the received data is read from the SBI0DBR.
external clock pulse, the received data should be read from the SBI0DBR before
the next serial clock pulse is input. If the received data is not read, further data to
be received is canceled. The maximum transfer speed when an external clock is
used is determined by the delay time between the time when an interrupt request
is generated and the time when the received data is read.
interrupt service program or when the <SIOINH> is set to “1”. If <SIOS> is
cleared to “0”, received data is transferred to the SBI0DBR in complete blocks.
The received mode ends when the transfer is completed. In order to confirm
whether data is being received properly by the program, the SBI0SR<SIOF> to be
sensed. The <SIOF> is cleared to “0” when receiving is completed. When it is
confirmed that receiving has been completed, the last data is read. When the
<SIOINH> is set to “1”, data receiving stops. The <SIOF> is cleared to “0” (The
received data becomes invalid, therefore no need to read it).
Set the control register to receive mode and set the SBI0CR1<SIOS> to “1” for
When the internal clock is used, the serial clock will stop and the automatic
When the external clock is used, since shift operation is synchronized with an
Receiving of data ends when the <SIOS> is cleared to “0” by the INTSBE0
SCK pin
<SIOF>
SO pin
Bit6
92CM22-196
Bit7
t
SODH
= 3.5/f
SYS
[s] (Min)
TMP92CM22
2007-02-16

Related parts for TMP92xy22FG