EP1S40B956C5 Altera, EP1S40B956C5 Datasheet - Page 784

IC STRATIX FPGA 40K LE 956-BGA

EP1S40B956C5

Manufacturer Part Number
EP1S40B956C5
Description
IC STRATIX FPGA 40K LE 956-BGA
Manufacturer
Altera
Series
Stratix®r
Datasheet

Specifications of EP1S40B956C5

Number Of Logic Elements/cells
41250
Number Of Labs/clbs
4125
Total Ram Bits
3423744
Number Of I /o
683
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
956-BGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S40B956C5
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S40B956C5
Manufacturer:
ALTERA
0
Part Number:
EP1S40B956C5
Manufacturer:
ALTERA
Quantity:
1
Part Number:
EP1S40B956C5
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP1S40B956C5N
Manufacturer:
ALTERA
0
Remote Configuration Operation
12–6
Stratix Device Handbook, Volume 2
Figure 12–5. Page Mode Feature in Stratix or Stratix GX Devices & Enhanced
Configuration Devices
Upon power-up in remote configuration mode, the factory configuration
(see description below) selects the user-specified page address through
the Stratix or Stratix GX PGM[2..0] output pins. These pins drive the
PGM[2..0] input pins of the enhanced configuration device and select
the requested page in the memory.
If an intelligent host is used instead of an enhanced configuration device,
you should create logic in the intelligent host to support page mode
settings similar to that in enhanced configuration devices.
Factory Configuration
Factory configuration is the default configuration data setup. In enhanced
configuration devices, this default page address is 000. Factory
configuration data is written into the memory device only once by the
system manufacturer and should not be remotely updated or altered. In
remote configuration mode, the factory configuration loads into the
Stratix or Stratix GX device upon power-up.
The factory configuration specifications are as follows:
Receives new configuration data and writes it to the enhanced
configuration or other memory devices
Determines the page address for the next application configuration
that should be loaded to the Stratix or Stratix GX device
Upon an error in the application configuration, the system reverts to
the factory configuration
Determines the reason for any application configuration error
Determines whether to enable or disable the user watchdog timer for
application configurations
Enhanced Configuration
Stratix 1
POF 1
Page0
POF 8
Device
tix7
Page Select
Altera Corporation
Stratix GX
Stratix or
Device
September 2004

Related parts for EP1S40B956C5