R5S72611 RENESAS [Renesas Technology Corp], R5S72611 Datasheet - Page 138

no-image

R5S72611

Manufacturer Part Number
R5S72611
Description
32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7260 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R5S72611P100FP
Manufacturer:
ACTEL
Quantity:
90
Part Number:
R5S72611P100FP
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
R5S72611P100FPV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
R5S72611RB120FPV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 5 Exception Handling
5.3.2
When an address error occurs, address error exception handling starts after the bus cycle in which
the address error occurred ends and execution of the instruction being executed completes. The
CPU operates as follows.
1. The exception service routine start address which corresponds to the address error that
2. The status register (SR) is saved to the stack.
3. The program counter (PC) is saved to the stack. The PC value saved is the start address of the
4. After jumping to the address fetched from the exception handling vector table, program
5.4
5.4.1
In bus monitor, notification of bus error occurrence to the CPU can be set. The notification is
generated when incorrect address access or bus timeout is detected. For details, see section 10,
Bus Monitor.
5.4.2
When a bus error occurs, bus error exception handling starts after the bus cycle in which the bus
error occurred ends and execution of the instruction being executed completes. The CPU operates
as follows.
1. The exception service routine start address which corresponds to the bus error that occurred is
2. The status register (SR) is saved to the stack.
3. The program counter (PC) is saved to the stack. The PC value saved is the start address of the
4. After jumping to the address fetched from the exception handling vector table, program
Rev. 2.00 Sep. 07, 2007 Page 106 of 1312
REJ09B0320-0200
occurred is fetched from the exception handling vector table.
instruction to be executed after the last executed instruction.
execution starts. The jump that occurs is not a delayed branch.
fetched from the exception handling vector table.
instruction to be executed after the last executed instruction.
execution starts. The jump that occurs is not a delayed branch.
Address Error Exception Handling
Bus Error
Bus Error Generation Source
Bus Error Exception Handling

Related parts for R5S72611