peb3456 Infineon Technologies Corporation, peb3456 Datasheet - Page 385

no-image

peb3456

Manufacturer Part Number
peb3456
Description
Channelized T3 Termination With Ds3 Framer, M13 Multiplexer, T1/ E1 Framers And 256 Channel Hdlc/ppp Controller
Manufacturer
Infineon Technologies Corporation
Datasheet
XSAW2
Transmit S
Access
Address
Reset Value
SA7
SA6
Data Sheet
15
a
Word 2
: read/write
: 12
: 0000
Transmit S
This bit field contains data to be transmitted in S
or an E1 multiframe. SA7 will be inserted into the data stream, if selected
via bit XCR2.SA7E.
E1: CRC-4 Multiframe
Transmit data will be aligned to a multiframe boundary. SA7(0) is the
data bit transmitted in frame one while SA7(7) is the data bit transmitted
in frame 15 of a multiframe.
Transmit S
This bit field contains data to be transmitted in S
or an E1 CRC-4 multiframe. SA6 will be inserted into the data stream, if
selected via bit XCR2.SA6E.
E1: CRC-4 Multiframe
Transmit data will be aligned to a multiframe boundary. SA6(0) is the
data bit transmitted in frame one while SA6(7) is the data bit transmitted
in frame 15 of a multiframe.
SA7(7:0)
H
H
a7
a6
Data Byte
Data Byte
8
385
7
SA6(7:0)
a7
a6
Register Description
of an E1 doubleframe
of an E1 doubleframe
PEB 3456 E
05.2001
0