peb3456 Infineon Technologies Corporation, peb3456 Datasheet - Page 331

no-image

peb3456

Manufacturer Part Number
peb3456
Description
Channelized T3 Termination With Ds3 Framer, M13 Multiplexer, T1/ E1 Framers And 256 Channel Hdlc/ppp Controller
Manufacturer
Infineon Technologies Corporation
Datasheet
TLCR1
T1/E1 Transmit Loop Code Register 1
Access
Address
Reset Value
LDC
LAC
Data Sheet
15
: read/write
: 03
: 0000
Line Loopback Deactuate Code
This bit field is sent in the outgoing bit stream if enabled via bit
TCMDR.XLD and TLCR0.LCS.
Note: Most significant bit is sent first. E.g. TCLR0.LDCL = 01
Line Loopback Actuate Code
This bit field is sent in the outgoing bit stream if enabled via bit
TCMDR.XLU and TLCR0.LCS.
Note: Most significant bit is sent first. E.g. TCLR0.LACL = 01
LDC(7:0)
H
H
code length to be six bits long. In this case LDC(5) is sent first.
code length to be six bits long. In this case LAC(5) is sent first.
8
331
7
LAC(7:0)
Register Description
PEB 3456 E
B
B
specifies
specifies
05.2001
0