S912XEP768J5MAGR Freescale Semiconductor, S912XEP768J5MAGR Datasheet - Page 711

no-image

S912XEP768J5MAGR

Manufacturer Part Number
S912XEP768J5MAGR
Description
16-bit Microcontrollers - MCU 16-bit 768K Flash
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S912XEP768J5MAGR

Rohs
yes
Core
HCS12X
Processor Series
MC9S12
Data Bus Width
16 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
768 KB
Data Ram Size
48 KB
On-chip Adc
Yes
Operating Supply Voltage
3.3 V to 5 V
Operating Temperature Range
- 40 C to + 125 C
Package / Case
LQFP-144
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S912XEP768J5MAGR
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Clock A is used as an input to an 8-bit down counter. This down counter loads a user programmable scale
value from the scale register (PWMSCLA). When the down counter reaches one, a pulse is output and the
8-bit counter is re-loaded. The output signal from this circuit is further divided by two. This gives a greater
range with only a slight reduction in granularity. Clock SA equals clock A divided by two times the value
in the PWMSCLA register.
Similarly, clock B is used as an input to an 8-bit down counter followed by a divide by two producing clock
SB. Thus, clock SB equals clock B divided by two times the value in the PWMSCLB register.
As an example, consider the case in which the user writes $FF into the PWMSCLA register. Clock A for
this case will be E divided by 4. A pulse will occur at a rate of once every 255x4 E cycles. Passing this
through the divide by two circuit produces a clock signal at an E divided by 2040 rate. Similarly, a value
of $01 in the PWMSCLA register when clock A is E divided by 4 will produce a clock at an E divided by
8 rate.
Otherwise, when changing rates the counter would have to count down to $01 before counting at the proper
rate. Forcing the associated counter to re-load the scale register value every time PWMSCLA or
PWMSCLB is written prevents this.
19.4.1.3
Each PWM channel has the capability of selecting one of two clocks. For channels 0, 1, 4, and 5 the clock
choices are clock A or clock SA. For channels 2, 3, 6, and 7 the choices are clock B or clock SB. The clock
selection is done with the PCLKx control bits in the PWMCLK register.
Freescale Semiconductor
Writing to PWMSCLA or PWMSCLB causes the associated 8-bit down counter to be re-loaded.
Clock Select
Clock SA = Clock A / (2 * PWMSCLA)
When PWMSCLA = $00, PWMSCLA value is considered a full scale value
of 256. Clock A is thus divided by 512.
Clock SB = Clock B / (2 * PWMSCLB)
When PWMSCLB = $00, PWMSCLB value is considered a full scale value
of 256. Clock B is thus divided by 512.
Writing to the scale registers while channels are operating can cause
irregularities in the PWM outputs.
Changing clock control bits while channels are operating can cause
irregularities in the PWM outputs.
MC9S12XE-Family Reference Manual Rev. 1.25
NOTE
NOTE
NOTE
NOTE
Chapter 19 Pulse-Width Modulator (S12PWM8B8CV1)
711

Related parts for S912XEP768J5MAGR