Datasheet

Specifications of S912XEP768J5MAGR

Rohs
yes
Core
HCS12X
Processor Series
MC9S12
Data Bus Width
16 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
768 KB
Data Ram Size
48 KB
On-chip Adc
Yes
Operating Supply Voltage
3.3 V to 5 V
Operating Temperature Range
- 40 C to + 125 C
Package / Case
LQFP-144
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S912XEP768J5MAGR
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
All bits reset to zero.
The two 8-bit pulse accumulators PAC1 and PAC0 are cascaded to form the PACB 16-bit pulse
accumulator. When PACB in enabled, (PBEN = 1 in PBCTL) the PACN1 and PACN0 registers contents
are respectively the high and low byte of the PACB.
When PACN1 overflows from 0x00FF to 0x0000, the interrupt flag PBOVF in PBFLG is set.
Full count register access will take place in one clock cycle.
14.3.2.19 16-Bit Modulus Down-Counter Control Register (MCCTL)
Read: Anytime
Write: Anytime
All bits reset to zero.
Freescale Semiconductor
Module Base + 0x0026
MODMC
RDMCL
Reset
Field
MCZI
7
6
5
W
R
MCZI
Modulus Counter Underflow Interrupt Enable
0 Modulus counter interrupt is disabled.
1 Modulus counter interrupt is enabled.
Modulus Mode Enable
0 The modulus counter counts down from the value written to it and will stop at 0x0000.
1 Modulus mode is enabled. When the modulus counter reaches 0x0000, the counter is loaded with the latest
Note: For proper operation, the MCEN bit should be cleared before modifying the MODMC bit in order to reset
Read Modulus Down-Counter Load
0 Reads of the modulus count register (MCCNT) will return the present value of the count register.
1 Reads of the modulus count register (MCCNT) will return the contents of the load register.
0
7
value written to the modulus count register.
A separate read/write for high byte and low byte will give a different result
than accessing them as a word.
When clocking pulse and write to the registers occurs simultaneously, write
takes priority and the register is not incremented.
Figure 14-42. 16-Bit Modulus Down-Counter Control Register (MCCTL)
the modulus counter to 0xFFFF.
MODMC
0
6
MC9S12XE-Family Reference Manual Rev. 1.25
Table 14-23. MCCTL Field Descriptions
RDMCL
0
5
ICLAT
NOTE
0
0
4
Description
FLMC
0
0
3
Chapter 14 Enhanced Capture Timer (ECT16B8CV3)
MCEN
0
2
MCPR1
0
1
MCPR0
0
0
553