SAF1761BE/V1,518 NXP Semiconductors, SAF1761BE/V1,518 Datasheet - Page 74

no-image

SAF1761BE/V1,518

Manufacturer Part Number
SAF1761BE/V1,518
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SAF1761BE/V1,518

Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SAF1761BE/V1,518
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
Table 71.
SAF1761_1
Product data sheet
Bit
31 to 29
28 to 25
24
23 to 8
7 to 0
DW1
63 to 57
56 to 50
49 to 48
47
46
45 to 44
43 to 42
41 to 35
34 to 32
Start and complete split for bulk: bit description
Symbol
reserved
RL[3:0]
reserved
DataStartAddress
[15:0]
reserved
HubAddress[6:0]
PortNumber[6:0]
SE[1:0]
reserved
S
EPType[1:0]
Token[1:0]
DeviceAddress[6:0]
EndPt[3:1]
Access
-
SW — writes
-
SW — writes
-
SW — writes
SW — writes
SW — writes
-
SW — writes
SW — writes
SW — writes
SW — writes
SW — writes
Rev. 01 — 18 November 2009
Value Description
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Reload: If RL is set to 0h, hardware ignores the NakCnt value.
Set RL and NakCnt to the same value before a transaction. For
full-speed and low-speed transactions, set this field to 0000b.
Not applicable to isochronous start split and complete split.
-
Data Start Address: This is the start address for data that will
be sent or received on or from the USB bus. This is the internal
memory address and not the direct CPU address.
RAM address = (CPU address
-
Hub Address: This indicates the hub address.
Port Number: This indicates the port number of the hub or
embedded TT.
This depends on the endpoint type and direction. It is valid
only for split transactions.
complete split only.
-
This bit indicates whether a split transaction has to be
executed:
0 — High-speed transaction
1 — Split transaction
Endpoint Type:
00 — Control
10 — Bulk
Token: This field indicates the PID for this transaction.
00 — OUT
01 — IN
10 — SETUP
Device Address: This is the USB address of the function
containing the endpoint that is referred to by this buffer.
Endpoint: This is the USB address of the endpoint within the
function.
…continued
Table 72
Hi-Speed USB OTG controller
400h) / 8
applies to start split and
SAF1761
© NXP B.V. 2009. All rights reserved.
74 of 166

Related parts for SAF1761BE/V1,518